Identification of components of the indoor unit.
Identification of components of the outdoor unit.
Explains the function of each button on the remote control.
Describes the meaning of icons shown on the remote display.
Step-by-step instructions for operating the air conditioner.
Safety precautions and methods for cleaning the air conditioner unit.
Step-by-step guide for cleaning the air filter.
Information on recycling packing materials and unit disposal.
Troubleshooting common issues with air conditioners based on symptoms.
List of error codes and their troubleshooting steps for diagnosing faults.
Crucial safety rules for electrical connections during installation.
Essential guidelines for proper grounding of the air conditioner.
Guidance on selecting the best location for indoor unit installation.
Detailed steps for mounting the indoor unit's frame on the wall.
Instructions on drilling the necessary hole for refrigerant pipes.
How to route the refrigerant and drain pipes from the indoor unit.
Steps for connecting the refrigerant pipes to the indoor unit.
Guidance on installing the drain hose for condensate removal.
Instructions for connecting the electrical wiring to the indoor unit.
How to bundle the refrigerant pipes, drain hose, and power cord.
Final steps for mounting the indoor unit onto the wall bracket.
How to select and secure the mounting support for the outdoor unit.
Connecting the drain joint for the outdoor unit (cooling/heating models).
Placing and securing the outdoor unit onto its support.
Connecting the refrigerant pipes between indoor and outdoor units.
Connecting the electrical wiring to the outdoor unit.
Routing and securing the pipes and drain hose.
Procedure for removing air and moisture from the refrigerant lines.
Methods for checking refrigerant leaks using a detector or soap water.
Checklist of items to verify after the air conditioner installation is complete.
Steps to prepare for the initial operational test of the unit.
How to perform the initial test to ensure the unit functions correctly.
Specifications for standard, minimum, and maximum connection pipe lengths.
Maximum allowable height differences between indoor and outdoor units.
Guidelines for adding refrigerant oil and charge based on pipe length.
Table detailing refrigerant charging amounts based on pipe diameter.
Steps for preparing the pipe, including cutting, de-burring, insulating, and fitting nuts.
Procedure for expanding the pipe end and final inspection of the port.