3
The above data is subject to change without notice; please refer to the nameplate of the unit.
Outdoor
Side
Compressor Manufacturer/Trademark ZHUHAI LANDA COMPRESSOR CO., LTD
Compressor Model QXA-B080C190
Compressor Oil RB68EP
Compressor Type Rotary
L.R.A. A 17.00
Compressor RLA A 3.20
Compressor Power Input W 660
Overload Protector Internal
Throttling Method Capillary
Operation Temp ºC 16~30
Ambient Temp (Cooling) ºC 18~43
Ambient Temp (Heating) ºC -7~30
Condenser Form Aluminum Fin-copper Tube
Pipe Diameter mm Φ7
Rows-n Gap mm 2-1.4
Coil Length (LXDXW) mm 771X25.4X342.9
Fan Motor Speed(H/M/L) rpm 930/870/810
Output of Fan Motor W 60
Fan Motor RLA A 0.50
Fan Motor Capacitor μF 3.5
Air Flow Volume of Outdoor Side m
3
/h 850
Fan Type Axial-ow
Fan Diameter mm Φ353
Sound Pressure Level (H/M/L) dB (A) 57/55/53
Sound Power Level (H/M/L) dB (A) 67/65/63
Defrosting Method Automatic Defrosting