15
7 SPECIFICATION.
7 1 Physical Data.
NOTE
( ) Cooling capacities are rated at 95 amblent,80 entering dry bulb,67 entering wet
bulb.Units are suitableforoperationt2 0%ofnominal CFM.
( )Heating capacities are based on the following conditions:Indoor temperature 68
entering dry bulb, entering dry bulb,outdoor temperature 4 entering dry bulb,4359 5
entering dry bulb.
Tab.7-1
3Tons 3Tons
Cooling Only Heat Pump
Power voltage/phase/frequency 230V/1/60 230V/1/60
Cooling(Btu/h) 33500 33000
Heating(Btu/h) - 33000
EER/COP(Btu/h W) 11.0 11.0
SEER(Btu/W) 13.0 14.0
Length(mm) 1321 1321
Width(mm 958 958
Heightmm) 630 630
140 140
144 144
1339*968*660 1339*968*660
R410A R410A
throttle valve throttle valve
Compressor Quantity/Type 1/Rotor compressor 1/Rotor compressor
Rows 2.5 2.5
Fins per inch 17 17
Tube diameter(in.) φ5 φ7
Rows 4 4
Fins per inch 17 17
Tube diameter(mm) φ7 φ7
Quantity used/diameter(mm) 1/560 1/560
Type Propeller Propeller
Drive type direct direct
Quantity speeds 11
Quantity motors/power(kW) 1/0.11 1/0.11
Motor RPM 850 850
Total nominal CFM 2400 2400
Quantity used/diameter(in.) 1/10*10 1/10*10
Type FC centrifugal FC centrifugal
Drive type direct direct
Quantity speeds 2 2
Quantity motors/power(kW) 1/0.18 1/0.35
Motor RPM 640 750
Total nominal CFM 1100 1460
Outdoor Static PressurePa standardMinimum-Maximum)0 0
Indoor Static PressurePa standardMinimum-Maximum)37 37
Cooling Operation Range °F 63-118 63-118
Heating Operation Range °F - 19-90
Nominal ton
Net weigtKg
Gross weightKg
Packing dimension: LxWxH
Refrigerant type
Flow control
Capacity
Dimensions
Outdoor coil
Indoor coil
Outdoor fan
Model type
Indoor fan
Performance