51
Outdoor
Model
No. of
Zones
Indoor Unit
Capacity
(Unit No.)
Line Set
Required
(Liquid x Gas)
MLA036S4M
Indoor๎˜ƒUnit๎˜ƒA
1/4โ€๎˜ƒliq๎˜ƒ+๎˜ƒ1/2โ€๎˜ƒgas
Indoor๎˜ƒUnit๎˜ƒB
1/4โ€๎˜ƒliq๎˜ƒ+๎˜ƒ1/2โ€๎˜ƒgas
Indoor๎˜ƒUnit๎˜ƒC
1/4โ€๎˜ƒliq๎˜ƒ+๎˜ƒ3/8โ€๎˜ƒgas
Indoor๎˜ƒUnit๎˜ƒD
1/4โ€๎˜ƒliq๎˜ƒ+๎˜ƒ3/8โ€๎˜ƒgas
2
009๎˜ƒ(B)
1
๎˜ƒ1/4๎˜ƒin.๎˜ƒx๎˜ƒ3/8๎˜ƒin.
018 (A) 1/4๎˜ƒin.๎˜ƒx๎˜ƒ1/2๎˜ƒin.
2
009๎˜ƒ(B)
1
๎˜ƒ1/4๎˜ƒin.๎˜ƒx๎˜ƒ3/8๎˜ƒin.
024๎˜ƒ(A)
2, 3
3/8 in. x 5/8 in.
2
012 (A) 1/4๎˜ƒin.๎˜ƒx๎˜ƒ1/2๎˜ƒin.
012๎˜ƒ(B) 1/4๎˜ƒin.๎˜ƒx๎˜ƒ1/2๎˜ƒin.
2
012๎˜ƒ(B) 1/4๎˜ƒin.๎˜ƒx๎˜ƒ1/2๎˜ƒin.
018 (A) 1/4๎˜ƒin.๎˜ƒx๎˜ƒ1/2๎˜ƒin.
2
012๎˜ƒ(B) 1/4๎˜ƒin.๎˜ƒx๎˜ƒ1/2๎˜ƒin.
024๎˜ƒ(A)
2, 3
3/8 in. x 5/8 in.
2
018๎˜ƒ(B) 1/4๎˜ƒin.๎˜ƒx๎˜ƒ1/2๎˜ƒin.
018 (A) 1/4๎˜ƒin.๎˜ƒx๎˜ƒ1/2๎˜ƒin.
2
018๎˜ƒ(B) 1/4๎˜ƒin.๎˜ƒx๎˜ƒ1/2๎˜ƒin.
024๎˜ƒ(A)
2, 3
3/8 in. x 5/8 in.
2
024๎˜ƒ(B)
2, 3
3/8 in. x 5/8 in.
024๎˜ƒ(A)
2, 3
3/8 in. x 5/8 in.
3
009 (A)
1
๎˜ƒ1/4๎˜ƒin.๎˜ƒx๎˜ƒ3/8๎˜ƒin.
009๎˜ƒ(B)
1
๎˜ƒ1/4๎˜ƒin.๎˜ƒx๎˜ƒ3/8๎˜ƒin.
009 (C) 1/4๎˜ƒin.๎˜ƒx๎˜ƒ3/8๎˜ƒin.
3
009๎˜ƒ(B)
1
๎˜ƒ1/4๎˜ƒin.๎˜ƒx๎˜ƒ3/8๎˜ƒin.
009 (C) 1/4๎˜ƒin.๎˜ƒx๎˜ƒ3/8๎˜ƒin.
012 (A) 1/4๎˜ƒin.๎˜ƒx๎˜ƒ1/2๎˜ƒin.
3
009๎˜ƒ(B)
1
๎˜ƒ1/4๎˜ƒin.๎˜ƒx๎˜ƒ3/8๎˜ƒin.
009 (C) 1/4๎˜ƒin.๎˜ƒx๎˜ƒ3/8๎˜ƒin.
018 (A) 1/4๎˜ƒin.๎˜ƒx๎˜ƒ1/2๎˜ƒin.
3
009 (C) 1/4๎˜ƒin.๎˜ƒx๎˜ƒ3/8๎˜ƒin.
009๎˜ƒ(B) 1๎˜ƒ1/4๎˜ƒin.๎˜ƒx๎˜ƒ1/2๎˜ƒin.
024๎˜ƒ(A)
2, 3
3/8 in. x 5/8 in.
3
009 (C) 1/4๎˜ƒin.๎˜ƒx๎˜ƒ3/8๎˜ƒin.
012 (A) 1/4๎˜ƒin.๎˜ƒx๎˜ƒ1/2๎˜ƒin.
012๎˜ƒ(B) 1/4๎˜ƒin.๎˜ƒx๎˜ƒ1/2๎˜ƒin.
3
009 (C) 1/4๎˜ƒin.๎˜ƒx๎˜ƒ3/8๎˜ƒin.
012๎˜ƒ(B) 1/4๎˜ƒin.๎˜ƒx๎˜ƒ1/2๎˜ƒin.
018 (A) 1/4๎˜ƒin.๎˜ƒx๎˜ƒ1/2๎˜ƒin.
3
009 (C) 1/4๎˜ƒin.๎˜ƒx๎˜ƒ3/8๎˜ƒin.
024๎˜ƒ(A)
2, 3
3/8 in. x 5/8 in.
012๎˜ƒ(B) 1/4๎˜ƒin.๎˜ƒx๎˜ƒ1/2๎˜ƒin.
3
009 (C) 1/4๎˜ƒin.๎˜ƒx๎˜ƒ3/8๎˜ƒin.
018 (A) 1/4๎˜ƒin.๎˜ƒx๎˜ƒ1/2๎˜ƒin.
018๎˜ƒ(B) 1/4๎˜ƒin.๎˜ƒx๎˜ƒ1/2๎˜ƒin.
3
012 (A) 1/4๎˜ƒin.๎˜ƒx๎˜ƒ1/2๎˜ƒin.
012๎˜ƒ(B) 1/4๎˜ƒin.๎˜ƒx๎˜ƒ1/2๎˜ƒin.
012 (C)
1
๎˜ƒ1/4๎˜ƒin.๎˜ƒx๎˜ƒ1/2๎˜ƒin.
1
3/8 x 1/2 in. gas pipe adaptor is required for line set connection to outdoor unit
(furnished๎˜ƒwith๎˜ƒoutdoor๎˜ƒunit).
2
๎˜ƒ๎˜ƒ1/4๎˜ƒx๎˜ƒ3/8๎˜ƒin.๎˜ƒliquid๎˜ƒpipe๎˜ƒadaptor๎˜ƒis๎˜ƒrequired๎˜ƒfor๎˜ƒline๎˜ƒset๎˜ƒconnection๎˜ƒto๎˜ƒthe๎˜ƒ048๎˜ƒ
outdoor๎˜ƒunit๎˜ƒ(furnished๎˜ƒwith๎˜ƒoutdoor๎˜ƒunit).
3
๎˜ƒ๎˜ƒ1/2๎˜ƒx๎˜ƒ5/8๎˜ƒin.๎˜ƒgas๎˜ƒpipe๎˜ƒadaptor๎˜ƒis๎˜ƒrequired๎˜ƒfor๎˜ƒline๎˜ƒset๎˜ƒconnection๎˜ƒto๎˜ƒthe๎˜ƒ048๎˜ƒoutdoor๎˜ƒ
unit๎˜ƒ(furnished๎˜ƒwith๎˜ƒoutdoor๎˜ƒunit).
4
๎˜ƒ๎˜ƒNot๎˜ƒa๎˜ƒvalid๎˜ƒcombination๎˜ƒwhen๎˜ƒusing๎˜ƒthe๎˜ƒMPA036S4M.
Outdoor
Model
No. of
Zones
Indoor Unit
Capacity
(Unit No.)
Line Set
Required
(Liquid x Gas)
MLA036S4M
Indoor๎˜ƒUnit๎˜ƒA
1/4โ€๎˜ƒliq๎˜ƒ+๎˜ƒ1/2โ€๎˜ƒgas
Indoor๎˜ƒUnit๎˜ƒB
1/4โ€๎˜ƒliq๎˜ƒ+๎˜ƒ1/2โ€๎˜ƒgas
Indoor๎˜ƒUnit๎˜ƒC
1/4โ€๎˜ƒliq๎˜ƒ+๎˜ƒ3/8โ€๎˜ƒgas
Indoor๎˜ƒUnit๎˜ƒD
1/4โ€๎˜ƒliq๎˜ƒ+๎˜ƒ3/8โ€๎˜ƒgas
3
012๎˜ƒ(B) 1/4๎˜ƒin.๎˜ƒx๎˜ƒ1/2๎˜ƒin.
012 (C)
1
๎˜ƒ1/4๎˜ƒin.๎˜ƒx๎˜ƒ1/2๎˜ƒin.
018 (A) 1/4๎˜ƒin.๎˜ƒx๎˜ƒ1/2๎˜ƒin.
3
012๎˜ƒ(B) 1/4๎˜ƒin.๎˜ƒx๎˜ƒ1/2๎˜ƒin.
012 (C)
1
๎˜ƒ1/4๎˜ƒin.๎˜ƒx๎˜ƒ1/2๎˜ƒin.
024๎˜ƒ(A)
2, 3
3/8 in. x 5/8 in.
3
012 (C)
1
๎˜ƒ1/4๎˜ƒin.๎˜ƒx๎˜ƒ1/2๎˜ƒin.
018 (A) 1/4๎˜ƒin.๎˜ƒx๎˜ƒ1/2๎˜ƒin.
018๎˜ƒ(B) 1/4๎˜ƒin.๎˜ƒx๎˜ƒ1/2๎˜ƒin.
4
009๎˜ƒ(B)
1
๎˜ƒ1/4๎˜ƒin.๎˜ƒx๎˜ƒ3/8๎˜ƒin.
009 (C) 1/4๎˜ƒin.๎˜ƒx๎˜ƒ3/8๎˜ƒin.
009๎˜ƒ(D) 1/4๎˜ƒin.๎˜ƒx๎˜ƒ3/8๎˜ƒin.
009 (A)
1
๎˜ƒ1/4๎˜ƒin.๎˜ƒx๎˜ƒ3/8๎˜ƒin.
4
009๎˜ƒ(B)
1
๎˜ƒ1/4๎˜ƒin.๎˜ƒx๎˜ƒ3/8๎˜ƒin.
009 (C) 1/4๎˜ƒin.๎˜ƒx๎˜ƒ3/8๎˜ƒin.
009๎˜ƒ(D) 1/4๎˜ƒin.๎˜ƒx๎˜ƒ3/8๎˜ƒin.
012 (A) 1/4๎˜ƒin.๎˜ƒx๎˜ƒ1/2๎˜ƒin.
4
009๎˜ƒ(B)
1
๎˜ƒ1/4๎˜ƒin.๎˜ƒx๎˜ƒ3/8๎˜ƒin.
009 (C) 1/4๎˜ƒin.๎˜ƒx๎˜ƒ3/8๎˜ƒin.
009๎˜ƒ(D) 1/4๎˜ƒin.๎˜ƒx๎˜ƒ3/8๎˜ƒin.
018 (A) 1/4๎˜ƒin.๎˜ƒx๎˜ƒ1/2๎˜ƒin.
4
009 (C) 1/4๎˜ƒin.๎˜ƒx๎˜ƒ3/8๎˜ƒin.
009๎˜ƒ(D) 1/4๎˜ƒin.๎˜ƒx๎˜ƒ3/8๎˜ƒin.
012 (A) 1/4๎˜ƒin.๎˜ƒx๎˜ƒ1/2๎˜ƒin.
012๎˜ƒ(B) 1/4๎˜ƒin.๎˜ƒx๎˜ƒ1/2๎˜ƒin.
4
009 (C) 1/4๎˜ƒin.๎˜ƒx๎˜ƒ3/8๎˜ƒin.
009๎˜ƒ(D) 1/4๎˜ƒin.๎˜ƒx๎˜ƒ3/8๎˜ƒin.
012๎˜ƒ(B) 1/4๎˜ƒin.๎˜ƒx๎˜ƒ1/2๎˜ƒin.
018 (A) 1/4๎˜ƒin.๎˜ƒx๎˜ƒ1/2๎˜ƒin.
4
009๎˜ƒ(D) 1/4๎˜ƒin.๎˜ƒx๎˜ƒ3/8๎˜ƒin.
012 (A) 1/4๎˜ƒin.๎˜ƒx๎˜ƒ1/2๎˜ƒin.
012๎˜ƒ(B) 1/4๎˜ƒin.๎˜ƒx๎˜ƒ1/2๎˜ƒin.
012 (C)
1
๎˜ƒ1/4๎˜ƒin.๎˜ƒx๎˜ƒ1/2๎˜ƒin.
4
012 (A) 1/4๎˜ƒin.๎˜ƒx๎˜ƒ1/2๎˜ƒin.
012๎˜ƒ(B) 1/4๎˜ƒin.๎˜ƒx๎˜ƒ1/2๎˜ƒin.
012 (C)
1
๎˜ƒ1/4๎˜ƒin.๎˜ƒx๎˜ƒ1/2๎˜ƒin.
012๎˜ƒ(D)
1
๎˜ƒ1/4๎˜ƒin.๎˜ƒx๎˜ƒ1/2๎˜ƒin.
1
3/8 x 1/2 in. gas pipe adaptor is required for line set connection to outdoor unit
(furnished๎˜ƒwith๎˜ƒoutdoor๎˜ƒunit).
2
๎˜ƒ๎˜ƒ1/4๎˜ƒx๎˜ƒ3/8๎˜ƒin.๎˜ƒliquid๎˜ƒpipe๎˜ƒadaptor๎˜ƒis๎˜ƒrequired๎˜ƒfor๎˜ƒline๎˜ƒset๎˜ƒconnection๎˜ƒto๎˜ƒthe๎˜ƒ048๎˜ƒ
outdoor๎˜ƒunit๎˜ƒ(furnished๎˜ƒwith๎˜ƒoutdoor๎˜ƒunit).
3
๎˜ƒ๎˜ƒ1/2๎˜ƒx๎˜ƒ5/8๎˜ƒin.๎˜ƒgas๎˜ƒpipe๎˜ƒadaptor๎˜ƒis๎˜ƒrequired๎˜ƒfor๎˜ƒline๎˜ƒset๎˜ƒconnection๎˜ƒto๎˜ƒthe๎˜ƒ048๎˜ƒoutdoor๎˜ƒ
unit๎˜ƒ(furnished๎˜ƒwith๎˜ƒoutdoor๎˜ƒunit).
4
๎˜ƒ๎˜ƒNot๎˜ƒa๎˜ƒvalid๎˜ƒcombination๎˜ƒwhen๎˜ƒusing๎˜ƒthe๎˜ƒMPA036S4M.