MINI-SPLIT SYSTEMS SERVICE MANUAL
CORP1602-L9
3/2017
Supersedes 10/2016
WARNING
Improper installation, adjustment, alteration, service or maintenance can cause property damage, personal injury or loss
of life.
Installation and service must be performed by a licensed professional HVAC installer (or equivalent) or service agency

Table of Contents

Other manuals for Lennox MWMA012S4-*L

Questions and Answers

  • H
    hortonaaronAug 20, 2025
    What to do if my Lennox MWMA012S4-*L shows an outdoor EEPROM malfunction?
    • A
      Anne SmithAug 20, 2025
      If your Lennox Air Conditioner displays an outdoor EEPROM malfunction, try these steps: * Power off the unit, then restart it after 3 minutes. * If the issue persists, the outdoor main PCB may need to be replaced.
  • J
    Jennifer MendezAug 22, 2025
    What to do if my Lennox MWMA012S4-*L has low refrigerant?
    • M
      mauricetorresAug 22, 2025
      If your Lennox Air Conditioner has low refrigerant, add refrigerant according to system specifications.
  • S
    scott94Aug 25, 2025
    What to do if my Lennox MWMA012S4-*L has high or low voltage protection error?
    • C
      Christina HopkinsAug 25, 2025
      If your Lennox Air Conditioner displays a high or low voltage protection error, verify the voltage supply levels and correct if required.
  • C
    Courtney SanchezAug 26, 2025
    How to fix communication error between indoor and outdoor unit in Lennox Air Conditioner?
    • M
      Michael ReedAug 27, 2025
      To address a communication error between the indoor and outdoor units of your Lennox Air Conditioner, check the communication wiring and connections.
  • A
    annette83Aug 28, 2025
    What to do if my Lennox MWMA012S4-*L Air Conditioner has a high water level alarm?
    • M
      Mr. Jeffrey CaseAug 28, 2025
      If your Lennox Air Conditioner is showing a high water level alarm, clear any blockage from the drain system.
  • R
    randysimmonsAug 29, 2025
    How to reset outdoor current overload on Lennox Air Conditioner?
    • K
      Kathryn TuckerAug 29, 2025
      If your Lennox Air Conditioner senses an outdoor current overload, reset the overload protection if it has tripped.
  • C
    Clayton PittsAug 31, 2025
    How to troubleshoot indoor fan speed error on Lennox MWMA012S4-*L?
    • M
      Matthew VargasAug 31, 2025
      To troubleshoot an indoor fan speed error on your Lennox Air Conditioner, inspect the fan and motor for proper operation.
  • K
    Kimberly HaasSep 2, 2025
    What to do if my Lennox MWMA012S4-*L Air Conditioner shows an outdoor unit fan speed error?
    • J
      Jennifer KingSep 2, 2025
      If your Lennox Air Conditioner displays an outdoor unit fan speed error, check the fan for operational issues.
  • P
    Peter DuarteSep 4, 2025
    How to fix compressor drive error in Lennox Air Conditioner?
    • M
      Michael LeeSep 4, 2025
      To fix a compressor drive error in your Lennox Air Conditioner, inspect the compressor and associated drive components.
  • T
    Travis PerezSep 6, 2025
    What to do for compressor pressure switch issues in Lennox MWMA012S4-*L?
    • A
      Amber AlvarezSep 6, 2025
      If your Lennox Air Conditioner has a compressor high-pressure or low-pressure switch open, investigate system pressures and correct abnormalities.

Summary

Single and Multiple Zone Outdoor Units

Outdoor Unit Clearances

Details necessary clearances around outdoor units for proper installation and airflow.

MCFA and MCFB Ceiling; Floor Indoor Units

Model Number Identification

Explains the model number structure for MCFA and MCFB ceiling/floor indoor units.

MPA, MPB and MLA Outdoor Unit Connections and Line Set Usage

Power Wiring for Outdoor and Indoor Units (Diagrams)

Connection to Centralized Controller

Set Indoor Unit Address for Centralized Control

Instructions for setting unique addresses for indoor units for centralized system control.

Start-Up

Adding Refrigerant - Single-Zone Systems

Procedures for adding the correct amount of refrigerant to single-zone systems.

Adding Refrigerant - Multi-Zone Systems

Procedures for adding the correct amount of refrigerant to multi-zone systems.

Quick Reference Guide - Error Codes

Single-Zone Outdoor Unit LED Locations

Multi-Zone Outdoor Unit LEDs and SW1 Locations

Troubleshooting Outdoor Unit Error Codes

Troubleshooting Indoor Unit Error Codes

Component Troubleshooting

Compressor Check

Steps to check compressor winding resistance and identify terminals.

IPM Check

Procedure to measure the resistance of the IPM windings.

Component Protection

Specifications and Operations

Capacity Request Calculations

Formula and methods for calculating system capacity requests based on conditions.

Defrost Control

Explains conditions and procedures for defrost control based on temperature and runtime.