TS − 3 to 5 Ton R−410A Air Conditioners / Page 18
ARI RATINGS
1
ARI Standard 210/240 Ratings
Cooling Capacity Efficiency
Total Unit
Indoor Unit Model No.
Expansion
Btuh SEER EER
Watts
ev
ce
tsa060s4 5 TON
Horizontal Indoor Coils + Furnace Horizontal Coils + Furnace
59,500 13.50 11.50 5185 CH33−60D−2F
4
G61MPV−60D−135
2
91M02
59,500 13.50 11.50 5185 CH33−60D−2F
4
G71MPP−60D−135
2
91M02
60,000 13.00 11.00 5455 CH33−62D−2F
4
G61MPV−60C−091
2
91M02
60,000 13.50 11.00 5255 CH33−50/60C−2F
4
G60UHV−60C−110
2
91M02
60,000 13.50 11.00 5310 CH33−50/60C−2F
4
G61MPV−60C−110
2
91M02
60,000 13.50 11.00 5310 CH33−50/60C−2F
4
G71MPP−60C−110
2
91M02
60,000 13.50 11.50 5215 CH33−62D−2F
4
G60UHV−60C−090
2
91M02
60,000 13.50 11.50 5215 CH33−62D−2F
4
G60UHV−60C−110
2
91M02
60,000 13.50 11.00 5455 CH33−62D−2F
4
G61MPV−60C−090
2
91M02
60,000 13.50 11.00 5455 CH33−62D−2F
4
G71MPP−60C−090
2
91M02
60,000 13.50 11.50 5215 CH33−62D−2F
4
G61MPV−60C−110
2
91M02
60,000 13.50 11.50 5215 CH33−62D−2F
4
G71MPP−60C−110
2
91M02
60,000 13.50 11.00 5455 CH33−62D−2F
4
G61MPV−60C−111
2
91M02
60,000 13.50 11.50 5185 CH33−62D−2F
4
G61MPV−60D−135
2
91M02
60,000 13.50 11.50 5185 CH33−62D−2F
4
G71MPP−60D−135
2
91M02
60,500 13.50 11.00 5500 CH33−50/60C−2F
4
G60UHV−60C−090
2
91M02
60,500 13.50 11.50 5195 CH33−60D−2F
4
G60UHV−60D−135
2
91M02
61,000 14.00 11.50 5200 CH33−62D−2F
4
G60UHV−60D−135
2
91M02
61,000 14.00 11.50 5200 CH23−68
4
G61MPV−60D−135
2
91M02
61,000 14.00 11.50 5200 CH23−68
4
G71MPP−60D−135
2
91M02
61,500 14.00 11.50 5215 CH23−68
4
G60UHV−60D−135
2
91M02
Air Handlers Air Handlers
56,500 12.00 10.20 5530
3
CB29M−65 (Multi−Position)
2
91M02
58,500 13.50 11.00 5145
3
CBX32M−048 (Multi−Position) Factory TXV
59,000 13.50 11.00 5365
4
CBX27UH−060 (Up−Flow / Horizontal) Factory TXV
59,500 13.00 11.00 5310
3
CBX32M−060 (Multi−Position) Factory TXV
59,500 13.50 11.00 5250
4
CBX32MV−048 (Multi−Position) Factory TXV
60,000 13.50 11.00 5260
4
CBX32MV−060 (Multi−Position) Factory TXV
62,500 14.00 11.50 5265 CBX26UH−060 (Up−Flow/Horizontal) Factory TXV
1
Certified in accordance with USE certification program which is based on ARI Standard 210/240; 95_F outdoor air temperature, 80_F db/67_F wb entering evaporator air
with 25 ft. of connecting refrigerant lines.
2
Factory installed RFC or expansion valve on indoor unit MUST be replaced with expansion valve kit (ordered separately) shown.
3
Blower must be capable of time−off blower delay. Indoor Blower Off Delay Relay (58M81) is recommended for field installation.
4
Blower control must be set for a time−off blower delay.