TS − 3 to 5 Ton R−410A Air Conditioners / Page 11
ARI RATINGS
1
ARI Standard 210/240 Ratings
Cooling Capacity Efficiency
Total Unit
Indoor Unit Model No.
Expansion
Btuh SEER EER
Watts
ev
ce
TSA036S4 3 TON
Horizontal Indoor Coils + Furnace Horizontal Coils + Furnace
33,800 13.50 11.00 3075 CH23−51
4
G61MPV−36B−070
2
37L51
33,800 13.50 11.00 3075 CH23−51
4
G71MPP−36B−070
2
37L51
34,000 13.00 11.00 3090 CH23−51
4
G61MPV−36B−045
2
37L51
34,200 14.00 11.60 2950 CH23−51
4
G60UHV−36B−090
2
37L51
34,800 13.50 11.50 3025 CH33−44/48B−2F
4
G61MPV−36B−070
2
37L51
34,800 13.50 11.50 3025 CH33−44/48B−2F
4
G71MPP−36B−070
2
37L51
35,000 13.50 11.00 3180 CH33−44/48B−2F
4
G61MPV−36B−045
2
37L51
35,200 13.50 11.50 3060 CH33−44/48B−2F
4
G61MPV−36B−071
2
37L51
35,200 14.00 11.60 3035 CH33−44/48B−2F
4
G60UHV−36B−090
2
37L51
35,600 14.00 11.60 3070 CH33−48C−2F
4
G61MPV−60C−090
2
37L51
35,600 14.00 11.60 3070 CH33−48C−2F
4
G61MPV−60C−110
2
37L51
35,600 14.00 11.60 3070 CH33−48C−2F
4
G71MPP−60C−090
2
37L51
35,600 14.00 11.60 3070 CH33−48C−2F
4
G71MPP−60C−110
2
37L51
Air Handlers Air Handlers
33,600 13.00 11.00 3055
3
CBX32M−030 (Multi−Position) Factory TXV
34,000 13.00 11.00 3090 CBX26UH−036 (Up−Flow / Horizontal) Factory TXV
34,200 12.80 10.70 3250
3
CB29M−46 (Multi−Position)
2
37L51
34,200 13.50 11.00 3110
3
CBX32M−036 (Multi−Position) Factory TXV
34,200 13.50 11.00 3110
3
CBX32M−042 (Multi−Position)
2
37L51
34,600 14.00 11.60 2985
4
CBX32MV−036 (Multi−Position) Factory TXV
35,200 13.50 11.50 3060
3
CBX32M−048 (Multi−Position)
2
37L51
35,600 14.00 12.00 2965
4
CBX32MV−048 (Multi−Position)
2
37L51
36,200 14.00 12.00 3015
3
CBX27UH−042 (Up−Flow / Horizontal)
2
37L51
TSA042S4 3.5 TON
Up-Flow Indoor Coils Up−Flow Coils
40,000 13.00 10.80 3700
3
CX34−38A/B−6F
2
39L72
40,000 13.00 10.80 3700
3
CX34−50/60C−6F
2
39L72
40,500 13.00 10.90 3710
3,
5
CX34−43B/C−6F Factory TXV
41,000 13.00 11.00 3715
3
CX34−49C−6F
2
39L72
Up-Flow Indoor Coils + Furnace Up−Flow Coils + Furnace
40,500 13.00 11.00 3690 CX34−38B−6F
4
G71MPP−36B−070
2
39L72
40,500 13.00 11.00 3690 CX34−38B−6F
4
G61MPV−36B−070
2
39L72
40,500 13.50 11.00 3555 CX34−38B−6F
4
G60UHV−36B−090
2
39L72
40,500 14.00 11.50 3485 CX34−50/60C−6F
4
G60UHV−60C−090
2
39L72
41,000 13.00 11.00 3680 CX34−43B−6F
4
G71MPP−36B−070 Factory TXV
41,000 13.00 11.00 3680 CX34−43B−6F
4
G61MPV−36B−070 Factory TXV
41,000 13.50 11.00 3590 CX34−50/60C−6F
4
G61MPV−60C−090
2
39L72
41,000 13.50 11.00 3590 CX34−50/60C−6F
4
G71MPP−60C−090
2
39L72
41,000 13.50 11.50 3575 CX34−49C−6F
4
G61MPV−60C−090
2
39L72
41,000 13.50 11.50 3575 CX34−49C−6F
4
G71MPP−60C−090
2
39L72
41,000 14.00 11.50 3475 CX34−49C−6F
4
G60UHV−60C−090
2
39L72
41,000 14.00 11.50 3490 CX34−43C−6F
4
G60UHV−60C−090 Factory TXV
Up-Flow Indoor Coils + Furnace Continued on Next Page
1
Certified in accordance with USE certification program which is based on ARI Standard 210/240; 95_F outdoor air temperature, 80_F db/67_F wb entering evaporator air
with 25 ft. of connecting refrigerant lines.
2
Factory installed RFC or expansion valve on indoor unit MUST be replaced with expansion valve kit (ordered separately) shown.
3
Blower must be capable of time−off blower delay. Indoor Blower Off Delay Relay (58M81) is recommended for field installation.
4
Blower control must be set for a time−off blower delay.
5
Most popular indoor coil.