TS − 3 to 5 Ton R−410A Air Conditioners / Page 16
ARI RATINGS
1
ARI Standard 210/240 Ratings
Cooling Capacity Efficiency
Total Unit
Indoor Unit Model No.
Expansion
Btuh SEER EER
Watts
ev
ce
tsa048s4 4 TON
Horizontal Indoor Coils + Furnace (Continued) Horizontal Coils + Furnace
48,000 14.00 11.50 4140 CH33−50/60C−2F
4
G60UHV−60C−110
2
91M02
48,500 13.50 11.00 4410 CH33−49C−2F
4
G61MPV−60C−091
2
91M02
48,500 13.50 11.50 4215 CH33−62D−2F
4
G61MPV−60C−091
2
91M02
48,500 14.00 11.50 4215 CH33−49C−2F
4
G60UHV−60C−090
2
91M02
48,500 14.00 11.50 4215 CH33−49C−2F
4
G60UHV−60C−110
2
91M02
48,500 14.00 11.50 4215 CH33−49C−2F
4
G61MPV−60C−090
2
91M02
48,500 14.00 11.50 4215 CH33−49C−2F
4
G71MPP−60C−090
2
91M02
48,500 14.00 11.50 4215 CH33−49C−2F
4
G61MPV−60C−110
2
91M02
48,500 14.00 11.50 4215 CH33−49C−2F
4
G71MPP−60C−110
2
91M02
48,500 14.00 11.50 4215 CH33−49C−2F
4
G61MPV−60C−111
2
91M02
48,500 14.00 11.50 4140 CH33−50/60C−2F
4
G60UHV−60C−090
2
91M02
48,500 14.00 11.50 4215 CH33−62D−2F
4
G60UHV−60C−090
2
91M02
48,500 14.00 11.50 4215 CH33−62D−2F
4
G60UHV−60C−110
2
91M02
48,500 14.00 11.50 4215 CH33−62D−2F
4
G71MPP−60C−090
2
91M02
48,500 14.00 11.50 4215 CH33−62D−2F
4
G61MPV−60C−090
2
91M02
48,500 14.00 11.50 4215 CH33−62D−2F
4
G71MPP−60C−110
2
91M02
48,500 14.00 11.50 4215 CH33−62D−2F
4
G61MPV−60C−110
2
91M02
48,500 14.00 11.50 4215 CH33−62D−2F
4
G61MPV−60C−111
2
91M02
48,500 14.00 12.00 4045 CH33−62D−2F
4
G60UHV−60D−135
2
91M02
48,500 14.00 11.50 4100 CH33−62D−2F
4
G71MPP−60D−135
2
91M02
48,500 14.00 11.50 4100 CH33−62D−2F
4
G61MPV−60D−135
2
91M02
Air Handlers Air Handlers
45,000 12.30 10.20 4385
3
CB29M−51 (Multi−Position)
2
91M02
47,500 13.50 11.00 4145
3
CBX32M−048 (Multi−Position) Factory TXV
47,500 14.00 11.50 4130
4
CBX27UH−048 (Up−Flow / Horizontal) Factory TXV
47,500 14.00 11.50 4130
4
CBX27UH−060 (Up−Flow / Horizontal) Factory TXV
48,000 13.50 11.50 4145
4
CBX32MV−048 (Multi−Position) Factory TXV
48,500 13.50 11.50 4210
3
CBX32M−060 (Multi−Position) Factory TXV
48,500 14.00 11.50 4150
4
CBX32MV−060 (Multi−Position) Factory TXV
48,500 14.00 11.50 4190 CBX26UH−048 (Up−Flow/Horizontal) Factory TXV
49,500 14.00 11.50 4195
3
CBX32M−042 (Multi−Position) Factory TXV
tsa060s4 5 TON
Up-Flow Indoor Coils Up−Flow Coils
59,000 13.00 11.00 5300
3,
5
CX34−49C−6F Factory TXV
60,000 13.00 11.00 5315
3
CX34−60D−6F Factory TXV
60,500 13.50 11.00 5320
3
CX34−62D−6F Factory TXV
61,500 13.50 11.50 5335
3
CX34−62C−6F Factory TXV
1
Certified in accordance with USE certification program which is based on ARI Standard 210/240; 95_F outdoor air temperature, 80_F db/67_F wb entering evaporator air
with 25 ft. of connecting refrigerant lines.
2
Factory installed RFC or expansion valve on indoor unit MUST be replaced with expansion valve kit (ordered separately) shown.
3
Blower must be capable of time−off blower delay. Indoor Blower Off Delay Relay (58M81) is recommended for field installation.
4
Blower control must be set for a time−off blower delay.
5
Most popular indoor coil.