TS − 3 to 5 Ton R−410A Air Conditioners / Page 15
ARI RATINGS
1
ARI Standard 210/240 Ratings
Cooling Capacity Efficiency
Total Unit
Indoor Unit Model No.
Expansion
Btuh SEER EER
Watts
ev
ce
tsa048s4 4 TON
Down-Flow Indoor Coils + Furnace Down−Flow Coils + Furnace
46,500 13.50 11.00 4085 CR33−60D−F
4
G61MPV−60D−135
2
91M02
46,500 13.50 11.00 4085 CR33−60D−F
4
G71MPP−60D−135
2
91M02
46,500 13.50 11.00 4100 CR33−50/60C−F
4
G60DFV−60C−110
2
91M02
46,500 13.50 11.00 4140 CR33−50/60C−F
4
G71MPP−60C−110
2
91M02
46,500 13.50 11.00 4140 CR33−50/60C−F
4
G61MPV−60C−110
2
91M02
46,500 13.50 11.00 4145 CR33−50/60C−F
4
G71MPP−60C−090
2
91M02
46,500 13.50 11.00 4145 CR33−50/60C−F
4
G61MPV−60C−090
2
91M02
47,000 13.50 11.00 4100 CR33−50/60C−F
4
G60DFV−60C−090
2
91M02
47,000 13.50 11.50 4075 CR33−60D−F
4
G60DFV−60D−135
2
91M02
Horizontal Indoor Coils Horizontal Coils
47,000 13.00 11.00 4260
3
CH33−44/48B−2F
2
91M02
47,000 13.00 11.00 4260
3
CH33−48C−2F
2
91M02
47,500 13.00 11.00 4320
3
CH33−43C−2F
2
91M02
47,500 13.00 11.00 4265
3
CH33−60D−2F
2
91M02
47,500 13.50 11.00 4265
3
CH23−68
2
91M02
48,000 13.50 11.00 4365
3
CH33−49C−2F
2
91M02
48,000 13.50 11.00 4265
3
CH33−50/60C−2F
2
91M02
48,000 13.50 11.00 4365
3
CH33−62D−2F
2
91M02
Horizontal Indoor Coils + Furnace Horizontal Coils + Furnace
47,500 13.50 11.00 4320 CH33−43C−2F
4
G71MPP−60C−090
2
91M02
47,500 13.50 11.00 4320 CH33−43C−2F
4
G61MPV−60C−090
2
91M02
47,500 13.50 11.00 4320 CH33−43C−2F
4
G61MPV−60C−091
2
91M02
47,500 13.50 11.00 4320 CH33−43C−2F
4
G61MPV−60C−110
2
91M02
47,500 13.50 11.00 4320 CH33−43C−2F
4
G71MPP−60C−110
2
91M02
47,500 13.50 11.00 4320 CH33−43C−2F
4
G61MPV−60C−111
2
91M02
47,500 13.50 11.00 4180 CH33−48C−2F
4
G61MPV−60C−090
2
91M02
47,500 13.50 11.00 4180 CH33−48C−2F
4
G71MPP−60C−090
2
91M02
47,500 13.50 11.00 4180 CH33−48C−2F
4
G61MPV−60C−110
2
91M02
47,500 13.50 11.00 4180 CH33−48C−2F
4
G71MPP−60C−110
2
91M02
47,500 13.50 11.50 4135 CH33−48C−2F
4
G60UHV−60C−110
2
91M02
47,500 13.50 11.50 4140 CH33−48C−2F
4
G60UHV−60C−090
2
91M02
48,000 13.50 11.50 4175 CH33−43C−2F
4
G60UHV−60C−110
2
91M02
48,000 13.50 11.50 4185 CH33−50/60C−2F
4
G71MPP−60C−090
2
91M02
48,000 13.50 11.50 4185 CH33−50/60C−2F
4
G61MPV−60C−090
2
91M02
48,000 13.50 11.50 4185 CH33−50/60C−2F
4
G71MPP−60C−110
2
91M02
48,000 13.50 11.50 4185 CH33−50/60C−2F
4
G61MPV−60C−110
2
91M02
48,000 14.00 11.50 4175 CH33−43C−2F
4
G60UHV−60C−090
2
91M02
48,000 14.00 11.50 4040 CH33−60D−2F
4
G60UHV−60D−135
2
91M02
48,000 14.00 11.50 4040 CH23−68
4
G60UHV−60D−135
2
91M02
48,000 14.00 11.50 4095 CH33−60D−2F
4
G71MPP−60D−135
2
91M02
48,000 14.00 11.50 4095 CH33−60D−2F
4
G61MPV−60D−135
2
91M02
48,000 14.00 11.50 4095 CH23−68
4
G71MPP−60D−135
2
91M02
48,000 14.00 11.50 4095 CH23−68
4
G61MPV−60D−135
2
91M02
Horizontal Indoor Coils + Furnace Continued on Next Page
1
Certified in accordance with USE certification program which is based on ARI Standard 210/240; 95_F outdoor air temperature, 80_F db/67_F wb entering evaporator air
with 25 ft. of connecting refrigerant lines.
2
Factory installed RFC or expansion valve on indoor unit MUST be replaced with expansion valve kit (ordered separately) shown.
3
Blower must be capable of time−off blower delay. Indoor Blower Off Delay Relay (58M81) is recommended for field installation.
4
Blower control must be set for a time−off blower delay.