XP17 - 2 to 5 Ton Heat Pump / Page 40
AHRI SYSTEM MATCHES
Model No.
Cooling
Capacity
SEER EER
Heat Capacity Heat COP
HSPF
(IV)
Coil or
Air Handler
Furnace
AHRI
Reference
High Low High Low
XP17-060-230 56,000 14.70 12.20 51,500 35,800 3.30 2.42 8.70 CX34-62C ML180UH090E60C 4666927
XP17-060-230 56,000 14.70 12.00 51,500 35,800 3.28 2.40 8.70 CX34-62C ML180UH110E60C 4666928
XP17-060-230 56,000 14.70 12.00 51,500 35,800 3.28 2.40 8.70 CX34-62C ML180UH110XE60C 4672134
XP17-060-230 56,000 14.70 12.20 51,500 35,800 3.30 2.40 8.70 CX34-62C SL280UH090V60C 3894879
XP17-060-230 56,000 14.70 12.20 51,500 35,800 3.30 2.40 8.70 CX34-62C SL280UH090XV60C 4235881
XP17-060-230 56,000 14.70 12.20 51,500 35,800 3.28 2.40 8.70 CX34-62C SL280UH110V60C 3894880
XP17-060-230 56,000 14.70 12.20 51,500 35,800 3.28 2.40 8.70 CX34-62C SL280UH110XV60C 4042039
XP17-060-230 55,500 14.50 12.00 51,500 35,800 3.24 2.38 8.50 CX34-62C SLP98UH090XV60C 5137377
XP17-060-230 55,500 14.70 12.20 51,000 35,600 3.22 2.38 8.50 CX34-62C SLP98UH110XV60C 5137378
XP17-060-230 56,500 14.20 12.00 52,000 36,200 3.28 2.38 8.50 CX34-62C 3840336
XP17-060-230 56,000 14.20 12.00 51,000 36,200 3.26 2.40 8.50 CX34-62D EL195UH135XE60D 4693671
XP17-060-230 56,000 14.70 12.20 51,000 35,800 3.24 2.40 8.50 CX34-62D EL296UH135XV60D 5054841
XP17-060-230 56,000 14.70 12.00 51,500 35,800 3.28 2.42 8.70 CX34-62D ML180UH135E60D 4666929
XP17-060-230 56,000 15.00 12.50 51,000 35,400 3.30 2.44 8.70 CX34-62D SL280UH135V60D 3894881
XP17-060-230 56,000 14.70 12.20 51,000 35,800 3.24 2.40 8.50 CX34-62D SLP98UH135XV60D 5136951
XP17-060-230 56,000 14.20 11.70 52,000 36,200 3.22 2.36 8.50 CX34-62D 3840345
NOTES:
Ratings are AHRI certied to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines);
• Cooling Ratings - 95°F outdoor air temperature and 80 °F db/67° F wb entering indoor coil air.
• High Temperature Heating Ratings - 47° F db/43° F wb outdoor air temperature and 70 °F db entering indoor coil air.
• Low Temperature Heating Ratings - 17 °F db/15° F wb outdoor air temperature and 70 °F db entering indoor coil air.
All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed Furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air
Handlers may require an optional time delay relay (58M81) for eld installation. See furnace or air handler specications to determine if relay is needed.
Also see TXV Substitution Table at the beginning of the Heat Pump AHRI System Matches section.
When used with gas furnaces, a dual-fuel control, a control system with dual-fuel capabilities (LZP-2 or LZP-4), or a thermostat with dual-fuel capabilities must be used
(order separately).
To convert HSPF from Region IV to Region V - Divide by 1.15.