Explanation: The firmware image capsule signature for the non-booted flash bank is invalid. Opposite
Bank CRTM Capsule Update Signature Invalid
Severity
Info
User Response
Complete the following steps:
1. Reflash backup UEFI image.
2. If error does not persist no additional recovery action is required.
3. If error persists, or boot is unsuccessful, replace the standard I/O book.
• I.3818003 The CRTM flash driver could not lock the secure flash region. CRTM Could not lock
secure flash region
Explanation: The CRTM flash driver could not lock the secure flash region. CRTM Could not lock secure
flash region
Severity
Info
User Response
Complete the following steps:
1. If system failed to boot successfully, DC cycle system.
2. If system boots to F1 setup, flash UEFI image and reset bank to primary (if required). If system
boots without error, recovery is complete and no additional action is required.
3. If system fails to boot, or if flash attempt fails, replace the standard I/O book
• I.3868000 BOFM: System reset performed to reset adapters. BOFM: System reset performed to
reset adapters
Explanation: BOFM: System reset performed to reset adapters. BOFM: System reset performed to reset
adapters
Severity
Info
User Response
Complete the following steps:
1. No user required for this event. This is for informational purposes only.
• I.3868003 BOFM: Configuration to large for compatibility mode. BOFM: Configuration too large for
compatibility mode
Explanation: BOFM: Configuration to large for compatibility mode. BOFM: Configuration too large for
compatibility mode
Severity
Info
User Response
Complete the following steps:
1. No user required for this event. This is for informational purposes only.
• I.58015 Memory spare copy initiated. Spare Copy Started
Explanation: Memory spare copy initiated. Spare Copy Started
Severity
Info