Memory error correcting code and parity test
Memory downsizing (non-mirrored memory). After a restart of the server after the memory controller
detects a non-mirrored uncorrectable error and the memory controller cannot recover operationally, the
IMM logs the uncorrectable error and informs POST. POST logically maps out the memory with the
uncorrectable error, and the server restarts with the remaining installed memory.
Memory mirroring and memory rank sparing support
Memory thermal throttling
Menu-driven setup, system configuration, and redundant array of independent disks (RAID) configuration
programs
Microprocessor built-in self-test (BIST), internal error signal monitoring, internal thermal trip signal
monitoring, configuration checking, and microprocessor and voltage regulator module failure identification
through light path diagnostics
Nonmaskable interrupt (NMI) button
Operating system memory on-lining (capacity change)
Parity checking on the PCIe buses
PCIe hot-add and remove support
PCIe hot-plug (microprocessor 2 and 3 only)
Power management: compliance with Advanced Configuration and Power Interface (ACPI)
Power-on self-test (POST)
Predictive Failure Analysis (PFA) alerts on memory, SAS/SATA hard disk drives or solid state drives, and
fans.
Redundant Ethernet capabilities with failover support
Redundant hot-swap power supplies and redundant hot-swap fans
Redundant network interface card (NIC) support
Remind button to temporarily turn off the system-error LED
Remote system problem-determination support
ROM-based diagnostics and upgrade of flash ROM-based code and diagnostics
ROM checksums
Serial Presence Detection (SPD) on memory, VPD on system board, power supply, and hard disk drive or
solid state drive backplanes, microprocessor and memory expansion tray, and Ethernet adapters
Single-DIMM isolation of excessive correctable error or multi-bit error by the Unified Extensible Firmware
Interface (UEFI)
SMI clock failover
SMI lane failover
SMI packet retry
Solid-state drives
Standby voltage for systems-management features and monitoring
Startup (boot) from LAN through remote initial program load (RIPL) or dynamic host configuration
protocol/boot protocol (DHCP/BOOTP)
System auto-configuring from the configuration menu
System-error logging (UEFI/POST and IMM)
Systems-management monitoring through the Inter-Integrated Circuit (I2C) protocol bus
Temperature and fan monitoring
Uncorrectable error (UE) detection
Upgradeable POST, Unified Extensible Firmware Interface (UEFI), diagnostics, IMM firmware, and read-
only memory (ROM) resident code, locally or over the LAN
Vital product data (VPD) on the microprocessor and memory expansion modules, PCIe expansion
modules, base I/O module, storage and I/O module, power supplies, and SAS/SATA (hot-swap hard disk
drive or solid state drive) backplanes
Wake on LAN capability