EasyManua.ls Logo

Lenovo System x3850 X6 - Page 376

Lenovo System x3850 X6
1990 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Latest level of DSA
180-901-000 : Check-point Panel Test Failed
Check-point Panel Test Failed. Operator reported incorrect display.
Recoverable
No
Severity
Error
Serviceable
Yes
Automatically notify support
No
User Response
Complete the following steps:
1. Check the operator information panel cabling for loose or broken connections at both ends or
damage to the cable.
2. Replace the information panel cable if damage is present.
3. Run the test again.
4. Replace the operator information panel assembly.
5. Run the test again.
6. If failure remains, refer to "Troubleshooting by symptom" in the system "Installation and Service
Guide" for the next corrective action.
Related links
Lenovo Support website
Latest level of DSA
DSA CPU stress test results
The following messages are generated when you run the CPU stress test.
Test results for the DSA CPU stress test
The following messages can result when you run the DSA CPU stress test.
089-000-000 : CPU Stress Test Passed
CPU Stress Test Passed.
Recoverable
No
Severity
Event
Serviceable
No
Automatically notify support
No
Related links
Lenovo Support website
Latest level of DSA
362 System x3850 X6 and x3950 X6 Installation and Service Guide

Other manuals for Lenovo System x3850 X6

Related product manuals