Recoverable
No
Severity
Warning
Serviceable
No
Automatically notify support
No
Related links
Lenovo Support website
Latest level of DSA
516-900-000 : ELXUCNA: NIC MAC LoopBackTest Failed
A failure was detected during the loopback test at the MAC layer.
Recoverable
No
Severity
Error
Serviceable
Yes
Automatically notify support
No
User Response
Complete the following steps:
1. Check component firmware level and upgrade if necessary. The installed firmware level can be
found in the DSA Diagnostic Event Log within the Firmware/VPD section for this component.
2. Rerun the test.
3. If failure remains, refer to "Troubleshooting by symptom" in the system "Installation and Service
Guide" for the next corrective action.
Related links
Lenovo Support website
Latest level of DSA
516-901-000 : ELXUCNA: NIC PHY LoopBackTest Failed
A failure was detected during the loopback test at the physical layer.
Recoverable
No
Severity
Error
Serviceable
Yes
Automatically notify support
No
User Response
Complete the following steps: