EasyManua.ls Logo

Lenovo System x3850 X6 - Page 391

Lenovo System x3850 X6
1990 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Serviceable
Yes
Automatically notify support
No
User Response
Complete the following steps:
1. Check the Ethernet cable for damage and ensure correct cable type and attachment.
2. Check component firmware level and upgrade if necessary. The installed firmware level can be
found in the DSA Diagnostic Event Log within the Firmware/VPD section for this component.
3. Rerun the test.
4. If failure remains, refer to "Troubleshooting by symptom" in the system "Installation and Service
Guide" for the next corrective action.
Related links
Lenovo Support website
Latest level of DSA
DSA LSI hard drive test results
The following messages are generated when you run the LSI hard drive test.
Test results for the DSA LSI hard drive test
The following messages can result when you run the DSA LSI hard drive test.
407-000-000 : LSIESG:DiskDefaultDiagnostic Test Passed
The test passed.
Recoverable
No
Severity
Event
Serviceable
No
Automatically notify support
No
Related links
Lenovo Support website
Latest level of DSA
407-800-000 : LSIESG:DiskDefaultDiagnostic Test Aborted
The test was canceled.
Recoverable
No
Severity
Warning
Serviceable
No
Automatically notify support
Appendix B. DSA diagnostic test results 377