User Response
Information only; no action is required.
40000026-00000000 : The [arg1] on system [arg2] is 100% full.
The IMM event log is full. New entries in the log will overwrite the oldest entries. To avoid losing older log
entries, save the log as a text file and clear the log.
May also be shown as 4000002600000000 or 0x4000002600000000
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
System - Event Log Fullness
SNMP Trap ID
35
CIM Information
Prefix: IMM ID: 0038
User Response
To avoid losing older log entries, save the log as a text file and clear the log.
40000027-00000000 : Platform Watchdog Timer expired for [arg1].
A Platform Watchdog Timer Expired event has occurred.
May also be shown as 4000002700000000 or 0x4000002700000000
Severity
Error
Serviceable
No
Automatically notify support
No
Alert Category
System - OS Timeout
SNMP Trap ID
21
CIM Information
Prefix: IMM ID: 0039
User Response
Complete the following steps until the problem is solved:
1. Reconfigure the watchdog timer to a higher value.
2. Make sure that the IMM Ethernet-over-USB interface is enabled.
3. Reinstall the RNDIS or cdc_ether device driver for the operating system.
4. Disable the watchdog.
5. Check the integrity of the installed operating system.
40000028-00000000 : Management Controller Test Alert Generated by [arg1].
492
System x3850 X6 and x3950 X6 Installation and Service Guide

Other manuals for Lenovo System x3850 X6