1. Check Lenovo support site for an applicable service bulletin or UEFI firmware update that applies to
this error.
2. A/C cycle the system.
3. If the problem persists, collect Service Data logs.
4. Contact Lenovo Support.
FQXSFDD0012I: SATA Hard Drive Error: [arg1] was recovered.
Severity: Info
User Action:
Information only; no action is required.
FQXSFDD0012K: SATA Hard Drive Error: [arg1].
Severity: Error
User Action:
Complete the following steps:
1. Power down the server.
2. Re-insert SATA Drive to ensure it is fully connected to the backplane.
3. If the problem persists, collect Service Data logs and contact Lenovo Support.
FQXSFIO0005M: An intra-board UPI failure has been detected on the link between processor [arg1]
port [arg2] and processor [arg3] port [arg4].
Severity: Error
User Action:
Complete the following steps:
1. Check Lenovo support site for an applicable service bulletin or firmware update that applies to this
error.
2. If the problem persists, collect Service Data logs.
3. Contact Lenovo Support.
FQXSFIO0006M: An inter-board UPI failure has been detected on the link between processor [arg1]
port [arg2] and processor [arg3] port [arg4].
Severity: Error
User Action:
Complete the following steps:
1. Check Lenovo support site for an applicable service bulletin or firmware update that applies to this
error.
2. If the problem persists, collect Service Data logs.
3. Contact Lenovo Support.
FQXSFIO0007M: An error has been detected by the IIO on Bus [arg1]. The value of Global Fatal
Error Status register is [arg2]. The value of Global Non-Fatal Error Status register is [arg3]. Please
check error logs for additional downstream device error data.
Severity: Error
User Action:
Complete the following steps:
Chapter 4. UEFI events 161