Information only; no action is required.
1D6F0030: SMM_POWER_ON: System Boot Initiated, Initiated by power up was asserted.
A event indicate SMM system power on
Severity: Informational
User Action:
Information only; no action is required.
21070150: NODE1_1ST_NOPERM: Slot Or Connector, transition to Non-Critical from OK was
asserted.
BMC failed to get the power permission to put the compute node into ready state.
Severity: Warning
User Action:
1. Check the PSU configuration
2. Check FAN status
3. Reset BMC
4. If error recurs, reseat compute node
5. If error recurs, replace the compute node
21070151: NODE2_1ST_NOPERM: Slot Or Connector, transition to Non-Critical from OK was
asserted.
BMC failed to get the power permission to put the compute node into ready state.
Severity: Warning
User Action:
1. Check the PSU configuration
2. Check FAN status
3. Reset BMC
4. If error recurs, reseat compute node
5. If error recurs, replace the compute node
21070152: NODE3_1ST_NOPERM: Slot Or Connector, transition to Non-Critical from OK was
asserted.
BMC failed to get the power permission to put the compute node into ready state.
Severity: Warning
User Action:
1. Check the PSU configuration
2. Check FAN status
3. Reset BMC
4. If error recurs, reseat compute node
5. If error recurs, replace the compute node
21070153: NODE4_1ST_NOPERM: Slot Or Connector, transition to Non-Critical from OK was
asserted.
BMC failed to get the power permission to put the compute node into ready state.
Severity: Warning
Chapter 2. SMM2 events 25