EasyManua.ls Logo

Lenz Digital plus LE1835A - Page 37

Lenz Digital plus LE1835A
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
37
E
This programming method uses two CVs (62, 63) for indicating and one CV (64) for transporting the
value. The procedure is as follows:
1. Programming the tens and units of the desired CV in the module in CV62.
2. Programming the hundreds of the desired CV in the module in CV63.
3. Reading/ programming the desired CV by reading/ programming CV64.
Example 1: You want to enter value 01 in the CV 897 of the S.U.S.I. module. Proceed as follows:
1. Enter the tens and units of 897, that is "97" in CV 62 (first indicator)
2. Enter the hundreds of 897, that is "8" in CV 63 (second indicator)
3. Enter the desired value "01" in the transport CV 64. The LE1835 will now transmit the
programming command "Enter value "01"" in CV "897"” via the S.U.S.I. interface to the
connected module.
Example 2: You want to read out the current value of the CV 902 of the S.U.S.I. module:
1. Enter the tens and units of 902, that is "02" in CV 62 (first indicator)
2. Enter the hundreds of 902, that is "9" in CV 63 (second indicator)
3. Read the CV 64. The value contained in the CV 902 of the connected module will be
displayed.