Electrical installation
Other application examples
EDK82ZBU DE/EN/FR 4.1
11
l
H1_E_INST−beisp_en
Other application examples
Starting/stopping (CINH) with the function module Standard−I/O
Switch/potentiometer unit
Wire bridge
CINH Controller inhibit /CINH Controller enable
Wiring for start/stop through switch
Terminal assignment
X3/20
Yellow wire
DC supply +20 V
X3/28 Grey wire
Start/stop
Pink wire = not used
Appropriate insulation!
Starting/stopping (CINH) with the function module Application−I/O
Switch/potentiometer unit
CINH Controller inhibit /CINH Controller enable
Wiring for start/stop through switch
Terminal assignment
X3/20
Yellow wire
DC supply +20 V
X3/28 Grey wire
Start/stop
Pink wire = not used
Appropriate insulation!
) Note!
Instead of using X3/28 also digital input (X3/E1 ... X3/E6) can be connected
and thus different digital functions, e.g. JOG1 on E1, can be activated.