EasyManua.ls Logo

Lenze g500 Series - Page 32

Lenze g500 Series
68 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Mechanical installation
Preparation
Coupling hubs
4
32
Lenze ¯ MA 12.0014 ¯ 5.1
Dismounting the clamping ring hub
1. Loosen the clamping screws evenly one after the other.
( Stop!
Each screw must only be loosened by half a revolution per pass! Unscrew
all clamping screws by 3 − 4 threads.
2. Remove the screws next to the forcing threads and screw them into the other
threads until they have contact.
3. Tighten the screws in the forcing threads crosswise and step−by−step so that the
clamping ring is loosened.
4. Clean and grease all contact surfaces including threads and head of the clamping
screws before reassembly.