Electrical installation
Connecting the supply and peripheral devices
Terminal diagram supply
6
30
BA_MP9000DVI DE 4.0
6.3 Connecting the supply and peripheral devices
6.3.1 Terminal diagram supply
L1
N
PE
L1
N
+
0V
+24
+
~ =
0 V
PE+24 V
+
0
1
F
S
MP9000DVI−006
Monitor panel
Power supply unit
Note!
Observe the max. permissible input voltage.
Professionally fuse the device on the input side against voltage variations and
voltage peaks.
6.3.2 24 V connection
Description Connection type Cable type
0V U
DC 24 V connection
3−pole Phoenix Combicon
socket
Cable (conductor
cross−section max. 2.5 mm
2
)
with Phoenix Combicon plug,
MSTB 2.5 / 3−STF−5.08
IPC001
PE connection M4 threaded bolt
Separate earthing conductor
(min. 2.5 mm
2
) with ring
cable lug
IPC001