EasyManua.ls Logo

Lenze MSEMA 080-32 Series - Page 62

Lenze MSEMA 080-32 Series
80 pages
Go to English
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Fuse data (F1 ... F3)
Motor MSEMA☐☐063-42 MSEMA☐☐080-32
Cable installaon in compli-
ance with
EN 60204-1
Installaon method B2
Fuse
Characteriscs gG/gL
Typ. rated current A 6 10
Max. rated current A 16 16
Semiconductor fuse
Characteriscs gRL
Typ. rated current A 6 10
Max. rated current A 16 16
Circuit breaker
Characteriscs C
Typ. rated current 6 10
Max. rated current A 16 16
Use of copper cables insulated with PVC
Conductor temperature < 70 °C, ambient temperature < 40 °C
No bundling of cables or wires, thee wires under load
Connecon for group drive according to EN 60204-1
L1
L2
L3
N
PE
F1 … F3
K
M
3~
+
A
1
I
N1
PE L1 L2 L3
M
3~
+
A
2
I
N2
PE L1 L2 L3
M
3~
+
A
3
I
N3
PE L1 L2 L3
M
3~
+
A
4
I
N4
PE L1 L2 L3
M
3~
+
A
n
I
Nn
PE L1 L2 L3
Max. total rated mains currents at 40 °C
Cable installaon in compli-
ance with
EN 60204-1
Laying system B2
cable cross‐secon
mm
2
1.5 2.5
(I
N1
+ L
N2
+ I
N3
+ I
Nn
) x 80% A 7.6 12.2
Fuse
Characteriscs gG/gL
Typ. rated current A --- ---
Max. rated current A 10 16
Circuit breaker
Characteriscs gRL
Typ. rated current A --- ---
Max. rated current A 10 16
Use of copper cables insulated with PVC
Conductor temperature < 70 °C, ambient temperature < 40 °C
No bundling of cables or wires, thee wires under load
Electrical installaon
Mains connecon
Connecon according to EN
62