WARNINGS AND CAUTIONS:
TO AVOID FIRE, SHOCK, OR DEATH; TURN OFF POWER AT CIRCUIT
BREAKER OR FUSE AND TEST THAT THE POWER IS OFF BEFORE WIRING!
To be installed and/or used in accordance with appropriate electrical codes
and regulations.
If you are not sure about any part of these instructions, consult an electrician.
This device CANNOT be used for separate feed applications. If the outlet you
are replacing has the top and bottom outlets controlled by separate circuit
breakers, you cannot use this device.
WARNINGS AND CAUTIONS:
To be used with Class 2 connectors with interconnecting cables.
The Class 2 USB ports are not intended for use with appliances and
supporting products.
All connected Class 2 output cables must be routed away from the
receptacle slots or any plug/cord inserted into the receptacle.
Use this device with copper or copper clad wire only.
Use this device with wires rated for at least 75°C.
For Technical Assistance Call: 1-800-824-3005 (U.S.A. Only) www.leviton.com
Duplex USB Charger/Tamper Resistant Outlet
Cat. No. T5633 (15A-125VAC/CA)
Cat. No. T5833 (20A-125VAC/CA)
USB Rated: 5.1A
PK-A3215-10-02-2B
The Duplex Type A & C USB Charger /Tamper Resistant Outlet provides:
- One Type A and one Type C 5VDC powered USB ports with a combined
Total of 5.1A charging current.
- Two 15A-125VAC or 20A-125VAC outlets.
The USB ports are used to charge portable electronic devices ONLY
(NO data transfer capability).
FEATURES
This device complies with Part 15 of the FCC rules. Operation is subject to the
following two conditions:
1. This device may not cause harmful interference.
2. This device must accept any interference received, including interference
that may cause undesired operation of the device.
This product is covered by U.S. Patent Nos. 7,355,117; 7,820,909; 7,868,719; 8,242,362 and corresponding foreign patents.
FCC COMPLIANCE STATEMENT
INSTALLATION
© 2017 Leviton Mfg. Co., Inc.
Neutral (White)
Neutre (Blanc)
Neutro (Blanco)
20A15A
Hot (Black)
Actif (Noir)
Fase (Negro)
Green
Ground
Terre vert
Verde a tierra
Type A
Type A
Tipo A
Type C
Type C
Tipo C
or
ou
o
Wiring Diagram
Schéma de cablâge
Diagrama de Alambrado
Strip Gage
Gabarit de dénudage
Medida de pelado
3/4"
(1.9 cm)
Third party company names, product names and/or trademarks are the property of their respective owners.
Use herein does not imply any afliation or endorsement.
LIMITED 5 YEAR WARRANTY AND EXCLUSIONS
Leviton warrants to the original consumer purchaser and not for the benet of anyone else that this product at the time of its sale by Leviton is free of defects in materials and workmanship under normal and proper
use for ve years from the purchase date. Leviton’s only obligation is to correct such defects by repair or replacement, at its option. For details visit www.leviton.com or call 1-800-824-3005. This warranty
excludes and there is disclaimed liability for labor for removal of this product or reinstallation. This warranty is void if this product is installed improperly or in an improper environment, overloaded, misused,
opened, abused, or altered in any manner, or is not used under normal operating conditions or not in accordance with any labels or instructions. There are no other or implied warranties of any kind, including
merchantability and tness for a particular purpose, but if any implied warranty is required by the applicable jurisdiction, the duration of any such implied warranty, including merchantability and tness for a
particular purpose, is limited to ve years. Leviton is not liable for incidental, indirect, special, or consequential damages, including without limitation, damage to, or loss of use of, any equipment,
lost sales or prots or delay or failure to perform this warranty obligation. The remedies provided herein are the exclusive remedies under this warranty, whether based on contract, tort or otherwise.
PK-A3215-10-02-2B
FOR CANADA ONLY
For warranty information and/or product returns, residents of Canada should contact Leviton in writing at Leviton Manufacturing of Canada Ltd to the attention of the Quality
Assurance Department, 165 Hymus Blvd, Pointe-Claire (Quebec), Canada H9R 1E9 or by telephone at 1 800 405-5320.
Use with Decora
®
wallplate
Utiliser avec plaque murale Decora
MD
Use con la placa de pared Decora
®
USB Charger
Chargeur USB
Cargador USB
Tamper Resistant
Outlet
Prise inviolable
Contacto con
Seguro
Compatible with most USB powered
devices including: tablets (Apple
iPad, Samsung Galaxy, Amazon
Kindle); smartphones (Apple iPhone,
Samsung Edge and Note,
Google Pixel, Motorola Moto Z);
laptops (Apple Macbook, Google
Chromebook, and Asus); and many more.
Compatibilité avec la plupart des appareils
à alimentation USB : tablettes (iPad d’Apple,
Galaxy de Samsung, Kindle d’Amazon),
téléphones intelligents (iPhone d’Apple,
Edge et Note de Samsung, Pixel de Google,
Moto Z de Motorola), portables (MacBook
d’Apple, Chromebook de Google et Asus)
et plus encore.
Compatible con la mayoría de los
dispositivos alimentados por USB,
incluyendo: tabletas (Apple iPad, Samsung
Galaxy, Amazon Kindle); teléfonos
inteligentes (iPhone de Apple, Samsung
Edge y Note, Google Pixel, Motorola Moto
Z); computadoras portátiles (Apple
Macbook, Google Chromebook y Asus);
y muchos más.
Duplex USB Charger
Tamper Resistant Outlet
Double Chargeur USB
Prise Inviolable
Doble Cargador USB
Contacto con Seguro
Charges most Type A and
Type C USB powered devices
Recharge la plupart des dispositifs
alimentés via USB de types A et C
Carga la mayoría de los dispositivos
alimentados por USB de Tipo A y Tipo C
1. WARNING: TO AVOID FIRE, SHOCK, OR DEATH; TURN OFF POWER
AT CIRCUIT BREAKER OR FUSE AND TEST THAT THE POWER IS OFF
BEFORE WIRING!
2. This device is to be installed in a wall box measuring at least
3" x 2" x 2-1/2" (standard single gang electrical wall box) and wired
in accordance with NEC article 314 box ll requirements.
3. Connect wires per WIRING DIAGRAM as follows:
NOTE: Back and Side wire terminals accept #14-#12 AWG copper or
copper clad wires.
4a. To Side Wire (if more than one wire is required on a terminal, you
cannot side wire and must use the backwire option):
Remove insulation from each circuit conductor per strip gage on device
[approx. 3/4" (1.9 cm)]. Loop wires clockwise 3/4 turn around terminal
screws. FIRMLY tighten screws over wire loop.
4b. To Back Wire: Remove insulation from each circuit conductor [approx.
1/2" ( 1.3 cm)]. Insert straight wires under clamps next to appropriate
terminal screws. Tighten screws FIRMLY.
5. Mount device in wall box with screws provided and mount wallplate.
6. Restore power at circuit breaker or fuse. Installation is complete.