EasyManua.ls Logo

LEYBOLD LV 80 - Page 18

Default Icon
62 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Description
18
300407956_002_C1 - 01/2017 - © Leybold
Fig. 1.6 Pumping Speed Curves for LEYVAC LV 80
0.0
1.0
2.0
3.0
4.0
5.0
0
25
50
75
100
0.001 0.01 0.1 1 10 100
[mbar]
60 Hz Pump Speed Air 50 Hz Pump Speed Air
50 Hz Power Air 60 Hz Power Air
[m
/h]
Power Consumption [kW]
Pumping Speed
Inlet Pressure
LEYVAC LV 80
Fig. 1.7 Pumping Speed Curves for LEYVAC LV 140
0.0
1.0
2.0
3.0
4.0
5.0
6.0
7.0
0
25
50
75
100
125
150
0.001 0.01 0.1 1 10 100
60 Hz Pump Speed Air 50 Hz Pump Speed Air
50 Hz Power Air 60 Hz Power Air
Power Consumption [kW]
Pumping Speed [m
3
/h]
Inlet Pressure [mbar]
LEYVAC LV 140

Related product manuals