EasyManua.ls Logo

LG 32LF550B - Page 13

LG 32LF550B
74 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
- 13 -
LGE Internal Use OnlyCopyright © LG Electronics. Inc. All rights reserved.
Only for training and service purposes
[Caution]
* Use the proper signal cable for EDID Download
- Analog EDID : Pin3 exists
- Digital EDID : Pin3 exists
* Edid data and Model option download (RS232)
(1) FHD 8BIT 2D HDMI EDID DATA
(2) Detail EDID Options are below
a. Product ID
b. Serial No: Controlled on production line.
c. Month, Year: Controlled on production line:
ex) Week : '01' -> '01'
Year : '2014' -> '18' fix
d. Model Name(Hex): Refer to the ASCII Code Table.
Cf) model name in EDID data is below.
e. Checksum: Changeable by total EDID data.
5.4. Outgoing condition Configuration
When pressing IN-STOP key by Service remote control,
Red LED are blinked alternatively. And then automatically
turn off. (Must not AC power OFF during blinking)
5.5. GND and HI-POT Test
5.5.1. GND & HI-POT auto-check preparation
(1) Check the POWER CABLE and SIGNAL CABE insertion
condition.
(2) You can’t use Tuner Ground & Tuner signal line at all
models (applied Isolator inner tuner)
5.5.2. GND & HI-POT auto-check
(1) Pallet moves in the station.(POWER CORD / AV CORD is
tightly inserted)
(2) Connect the AV JACK Tester.
(3) Controller (GWS103-4) on.
(4) GND Test (Auto)
- If Test is failed, Buzzer operates.
- If Test is passed, execute next process(Hi-pot test).
(Remove A/V CORD from A/V JACK BOX)
(5) HI-POT test (Auto)
- If Test is failed, Buzzer operates.
- If Test is passed, GOOD Lamp on and move to next
process automatically.
5.5.3. Checkpoint
(1) Test voltage
1) 3 Poles
- GND: 1.5 KV/min at 100 mA
- SIGNAL: 3 KV/min at 100 mA
2) 2 Poles
- SIGNAL: 3 KV/min at 100 mA
(2) TEST time: 1 second
(3) TEST POINT
1) 3 Poles
- GND Test = POWER CORD GND and SIGNAL
CABLE GND.
- Hi-pot Test = POWER CORD GND and LIVE &
NEUTRAL.
2) 2 Poles
- Hi-pot Test = Accessible Metal and LIVE & NEUTRAL.
(4) LEAKAGE CURRENT: At 0.5 mArms
NO Item CMD 1 CMD 2 Data 0
Enter download
Mode
Download
‘Mode In’
A A 0 0
When transfer the ‘Mode In’,
Carry the command.
EDID data and
Model option
download
Download A E 00 10
Automatically adjustment
(The use of a internal pattern)
No. Item Condition Hex Data
1 Manufacturer ID GSM 1E6D
2 Version Digital : 1 01
3 Revision Digital : 3 03
0 1 2 3 4 5 6 7 8 9 A B C D E F
0 0 ff ff ff ff ff ff 00 1E 6D a b
10 c 01 03 80 A0 5A 78 0A EE 91 A3 54 4C 99 26
20 0F 50 54 A1 08 00 31 40 45 40 61 40 71 40 01 01
30 01 01 01 01 01 01 66 21 50 B0 51 00 1B 30 40 70
40 36 00 40 84 63 00 00 1E 64 19 00 40 40 00 26 30
50 18 88 03 06 40 84 63 00 00 18 00 00 00 FD 00 3A
60 3E 1E 53 10 00 0A 20 20 20 20 20 20 d
70 d 01 e
80 02 03 22 F1 4E 10 1F 04 93 05 14 03 02 12 20 21
90 22 15 01 26 15 07 50 09 57 07 f
A0 80 1E 01 1D 80 18 71 1C 16 20 58 2C 25 00 A0 5A
B0 00 00 00 9E 01 1d 00 72 51 D0 1E 20 6E 28 55 00
C0 20 C2 31 00 00 1E 8C 0A D0 8A 20 E0 2D 10 10 3E
D0 96 00 A0 5A 00 00 00 18 02 3A 80 18 71 38 2D 40
E0 58 2C 45 00 A0 5A 00 00 00 1E 00 00 00 00 00 00
F0 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 e
Model Name HEX EDID Table DDC Function
HD/FHD Model 0001 01 00 Analog/Digital
MODEL NAME MODEL NAME(HEX)
LG TV 00 00 00 FC 00 4C 47 20 54 56 0A 20 20 20 20 20 20 20 (LG TV)
EDID C/S data
2D HD 2D(DTS)
HDMI HDMI
Check Sum
(Hex)
Block 0 74 74
Block 1
5B (HDMI1) 52 (HDMI1)
4B (HDMI2) 42 (HDMI2)

Related product manuals