31
ENGLISH
24
Fail Over Mode (Command: m i)
Selects the Fail Over mode.
Transmission
(m)(i)( )(Set ID)( )(Data)(Cr)
Data 00: Off
Data 01: Auto
Data 02: Manual
Ack
(i)( )(Set ID)( )(OK/NG)(Data)(x)
25
Fail Over Input Select (Command: m j)
Selects an input source for fail over. (This feature is
only available when Fail Over is set to Custom.)
Transmission
(m)(j)( )(Set ID)( )(Data 1)( )(Data 2)( )(Data 3)( )(Data
4)...( )(DataN)(Cr)
Data 1-N (Input priority 1-N)
Data 20: AV1
Data 21: AV2
Data 22: AV3
Data 90: HDMI1
Data 91: HDMI2
Data 92: HDMI3
Data 93: HDMI4
Ack
(j)( )(Set ID)( )(OK/NG)(Data 1)(Data 2)(Data 3)(Data
4)...(DataN)(x)
* Some input signals may not be available for all
models.
* The data number (N) may vary depending upon the
model. (The data number depends on the number
of supported input signals.)
26
Internal storage media contents play
(Command: s n, a8)
Plays media stored in the internal memory.
This command may work differently depending
upon model and signal.
Transmission
(s)(n)( )(Set ID)( )(a)(8)( )(Data)(Cr)
Data 01: Media contents play
Ack
(n)( )(Set ID)( )(OK/NG)(a)(8)( )(Data)(x)
* Real data mapping
00: Step 0
A: Step 10 (Set ID 10)
F: Step 15 (Set ID 15)
10: Step 16 (Set ID 16)
64: Step 100
6E: Step 110
73: Step 115
74: Step 116
CF: Step 199
FE: Step 254
FF: Step 255