◈Direct LED W/B adjust target value (Only LGD direct LED, LM3100/LM3400 series)
Cool Medium Warm
x y x y x y
Target
(Direct LED)
47LS4100-CA
LGD Edge LED 13000K 9300K 6500K O
42LS4100-CA
LGD Edge LED 13000K 9300K 6500K O
32LS3500-CA
LGD Edge LED 13000K 9300K 6500K O
42CS460-CB
LGD EEFL 11000K 9300K 6500K X
32CS460-CB
LGD EEFL 11000K 9300K 6500K X
42LM3400-CC
LGD Direct LED 13000K 9300K 6500K X
42LM3100-CC
LGD Direct LED 13000K 9300K 6500K X
32LM3100-CC
LGD Direct LED 13000K 9300K 6500K X
55LM4600-CC
LGD Edge LED 13000K 9300K 6500K O
47LM4600-CC
LGD Edge LED 13000K 9300K 6500K O
※ Connecting picture of the measuring instrument (On Automatic control)
Inside PATTERN is used when W/B is controlled. Connect to auto controller or push Adjustment R/C P-ONLY à
Enter the mode of White-Balance, the pattern will come out.
Auto-control interface and directions
1. Adjust in the place where the influx of light like floodlight around is blocked. (Illumination is less than 10ux).
2. Adhere closely the Color Analyzer ( CA210 ) to the module less than 10cm distance, keep it with the surface of
the Module and Color Analyzer’s Prove vertically.(80~100°).
3. Aging time
-. After aging start, keep the power on (no suspension of power supply) and heat-run over 5 minutes.
-. Using ‘no signal’ or ‘POWER ONLY’ or the others, check the back light on.