4.1.4 LAN inspection solution
LAN Port connection with PCB
Network setting at MENU Mode of TV
Setting automatic IP
Setting state confirmation
- If automatic setting is finished, you confirm IP and MAC
Address.
4.1.5 LAN Port Inspection (PING Test)
4.1.5.1 Equipment setting
1) Play the LAN Port Test PROGRAM.
2) Input IP set up for an inspection to Test Program.
*IP Number : 12.12.2.2
4.1.6 LAN Port Inspection (PING Test)
1) Play the LAN Port Test Program.
2) connect each other LAN Port Jack.
3) Play Test (F9) button and confirm OK Message.
4) remove LAN CABLE
4.2. Using RS-232C
Adjust 3 items at 3.1 PCB assembly adjustments adjustment
sequence one after the order.
A Adjustment protocol
See ADC Adjustment RS232C Protocol_Ver1.0
A Necessary items before Adjustment items
Pattern Generator : (MSPG-925FA)
Adjust 480i Comp1 (MSPG-925FA:model :209 , pattern
:65) Comp1 Mode
Adjust 1080p Comp1 (MSPG-925FA:model :225 ,
pattern :65) Comp1 Mode
Adjust RGB (MSPG-925FA:model :225 , Pattern :65)
RGB-PC Mode
* If you want more information then see the below
Adjustment method (Factory Adjustment)
A Adjustment sequence
aa 00 00: Enter the ADC Adjustment mode.
xb 00 40: Change the mode to Component1 (No actions)
ad 00 10: Adjust 480i Comp
ad 00 10: Adjust 1080p Comp
xb 00 60: Change to RGB-PC mode(No action)
ad 00 10: Adjust 1080p RGB
xb 00 90: Endo of Adjustmennt