5.1.6. Reference
(White Balance Adj. coordinate and color
temperature)
▪ Luminance: 204 Gray, 80IRE
**(normal line) Model : For LGD (LB56xx, LB55xx)
▪ Stand a rd colo r c o ordin a te and t emper a ture usi n g
CA-210(CH-14) – by aging time
H/R Time(Min)
Cool Medium Warm
x y x x y x
271 270 285 293 313 329
1 0-2 281 285 295 308 323 344
2 3-5 280 284 294 307 322 343
3 6-9 279 282 293 305 321 341
4 10-19 277 279 291 302 319 338
5 20-35 275 275 289 298 317 334
6 36-49 273 273 287 296 315 332
7 50-79 272 272 286 295 314 331
8 80-119 271 270 285 293 313 329
9 Over 120 271 270 285 293 313 329
**(aging chamber) Model : For LGD (LB56xx, LB55xx)
▪ Sta nda rd col or coo rdinate and temperatur e usi ng
CA-210(CH-14) – by aging time
H/R Time(Min)
Cool Medium Warm
x y x x y x
271 270 285 293 313 329
1 0-5 280 285 294 308 319 340
2 6-10 276 280 290 303 315 335
3 11-20 272 275 286 298 311 330
4 21-30 269 272 283 295 308 327
5 31-40 267 268 281 291 306 323
6 41-50 266 265 280 288 305 320
7 51-80 265 263 279 286 304 318
8 81-119 264 261 278 284 303 316
9 Over 120 264 260 278 283 303 315
5.2. Option selection per country
5.2.1. Overview
(1) Tool option selection is only done for models in Non-USA
North America due to rating
(2) Applied model: LA32B Chassis applied to CANADA and
MEXICO
5.2.2. Country Group selection
(1) Press ADJ key on the Adj. R/C, and then select Country
Group Menu
(2) Depending on destination, select US, then on the lower
Country option, select US, CA, MX.
Selection is done using +, - KEY
(3) Using DFT(Auto)
※ PC (for communication through RS-232C) -> UART Baud
rate : 115200 bps
Command : ah 00 00 DATA(Area Number(hexadecimal))
ITEM DATA(Area Number) AREA
AREA OPTION1 0 USA
1 CANADA
2 MEXICO
5.2.3. Tool Option inspection
▪ Press Adj. key on the Adj. R/C, then select Tool option
Model Module
Tool
option1
Tool
option2
Tool
option3
Tool
option4
32LB5600-UH LGD 00529 01030 24716 20544
32LB550B-UC LGD 00529 13314 24716 20544
42LB5600-UH LGD 01297 01030 24716 20544
42LB5600-UH AUO 09488 01030 24716 20544
39LB5600-UH INX
17426 01030 24716 20544
32LB560B-UH
SHARP
12816
(MIRROR?)
09218 24716 20544
32LB560B-UH
BOE
21008
(MIRROR?)
09218 24716 20544
32LB560B-UH LGD 00529 09218 24716 20544
55LB5500-UC BOE 22800 05126 24716 20544
55LB5500-UC LGD 02321 05126 24716 20544
49LB5500-UC LGD 01809 05126 24716 20544
42LB5500-UC LGD 01297 05126 24716 20544
32LB550B-UC SHARP 12816 13314 24716 20544
※ Tool option can be reconstructed by Software
5.3. Ship-out mode check (In-stop)
- After final inspection, press In-Stop key of the Adj. R/C and
check that the unit goes to Stand-by mode