Symptom
1) After once shining, it doesn’t discharge minutely from module.
2) The relay falls. ( The sound is audible "Click ")
3) It is converted w ith the c o lor where the front LED is red from gr een .
2. Protection mode
Start check
Is the PSU
no rmal?
Is the each
connector norma l?
Is t he Y- Board
no rmal ?
Is output the no rmality Lo w/High
Voltage except Stand-by 5V?
Replace the power board
After connecting we ll each
connector the normality it operates?
Replace the power board
Is no rmal the output voltage after
remove P1 connector of Y-B/D?
Replace Y-B/D
Is no rmal the fuse
(FS2,FS3 ) on Y-B/D?
Replace the fuse
Is the Z - Board
no rmal ?
Is no rmal the output vo ltage after
remove P1 connector of Z-B/D?
Replace Z -B/D
Is no rmal the fuse
(FS1,FS2 ) on Z-B/D?
Replace the fuse
Is t he X- Board
no rmal ?
After remove P100,110 output voltage normality:
Re place Ri ght X-B/ D
Afte r remo ve P200,210 output voltage normality:
Replace Left X- B/D
Is normal the output vo ltage
after remove P100,110,200, 210
connector of X- B/D?
YE S
YE S
YE S
YE S
YE S
YE S
NO
NO
NO
NO
NO
NO
NO