CHANGING YOUR CODE
(With
e
KEY or
e
KEY
II
)
ALWAYS PERFORM THIS OPERATION WITH THE DOOR OPEN
If your unit is programmed for Dual Code, each code must be changed independently.
1 Enter existing code and hold in key until unit double signals twice and the LED stays on. Leave the key in the unit.
2 Press the “0” key.
3 Enter your NEW six (6) digit code two times, touching the key after each complete six-digit code entry.
4 If a mistake is made wait thirty (30) seconds and repeat steps 1 - 3.
5 Test unit operation several times before closing the door.
Valid Code Entry - Double signal after valid six (6) digit code is entered.
• Invalid Code Entry - Triple signal and old code is still valid.
MANAGER CODE MUST BE CHANGED PRIOR TO PERFORMING ANY ACTION OTHER THAN OPENING THE LOCK
OPENING THE LOCK
(With
e
KEY or
e
KEY
II
)
1 Enter valid six (6) digit code and insert key.
2 The unit will indicate a valid code and key entry with a double signal.
3 Within four (4) seconds open lock by either rotating the keypad to open position (Clock-wise) or turning the handle to the open
position.
4 Pull door open.
• Invalid Code Entry - Unit will signal three (3) times.
ACTIVATING USER
(Manager Only, with
e
KEY or
e
KEY
II
)
ALWAYS PERFORM THIS OPERATION WITH THE DOOR OPEN
1 Enter Manager code and hold in key until unit double signals twice and the LED stays on. Remove key.
2 PRESS 1. Unit signals twice.
3 Press User number, 2 to 9. Unit signals twice.
4 Enter NEW six (6) digit User code two times, touching the key after each complete six-digit code entry.
5 If a mistake is made wait thirty (30) seconds and repeat steps 1 - 3.
Valid Code Entry - Double signal after valid six (6) digit code is entered.
• Invalid Code Entry - Triple signal and old code is still valid.
DISABLE USER
(Manager Only, with
e
KEY or
e
KEY
II
)
ALWAYS PERFORM THIS OPERATION WITH THE DOOR OPEN
1 Enter Manager code and hold in key until unit double signals twice and the LED stays on.
2 PRESS 2. Unit signals twice.
3 Press User number, 2 to 9. Unit signals once.
4 User is temporarily disabled.
5 If a mistake is made wait thirty (30) seconds and repeat steps 1 - 3.
Valid Code Entry - Double signal after valid six (6) digit code is entered.
• Invalid Code Entry - Triple signal and old code is still valid.
REINSTATE USER
(Manager Only, with
e
KEY or
e
KEY
II
)
ALWAYS PERFORM THIS OPERATION WITH THE DOOR OPEN
1 Enter Manager code and hold in key until unit double signals twice and the LED stays on.
2 PRESS 1. Unit signals twice.
3 Press User number, 2 to 9. Unit signals once.
4 User is reinstated.
5 If a mistake is made wait thirty (30) seconds and repeat steps 1 - 3.
Valid Code Entry - Double signal after valid six (6) digit code is entered.
• Invalid Code Entry - Triple signal and old code is still valid
.
DELETE USER
(Manager Only, with
e
KEY or
e
KEY
II
)
ALWAYS PERFORM THIS OPERATION WITH THE DOOR OPEN
1 Enter Manager code and hold in key until unit double signals twice and the LED stays on.
2 PRESS 3. Unit signals twice.
3 Press User number, 2 to 9. Unit signals once.
4 User is deleted.
5 If a mistake is made wait thirty (30) seconds and repeat steps 1 - 3.
Valid Code Entry - Double signal after valid six (6) digit code is entered.
• Invalid Code Entry - Triple signal and old code is still valid.
CHECK USER STATUS
(Manager Only, with
e
KEY or
e
KEY
II
)
ALWAYS PERFORM THIS OPERATION WITH THE DOOR OPEN
1 Enter Manager code and hold in key until unit double signals twice and the LED stays on.
2 PRESS AND HOLD DOWN 1. Unit signals twice.
3 Press User number, 2 to 9.
4 Unit will signal once is the user is active, twice is the user is disabled, three times if the User is available. The unit will signal with one
extended signal is the User is unavailable.
5 To exit PRESS 0 or 1.