© copyright 2006 12-239v3 LA GARD INC - A Member of The Kaba Group
4300 Dual-Handed Swingbolt or 6040-DB Deadbolt Lock Instructions
MANAGER PROGRAMMING
CHANGING YOUR CODE (Without
e
KEY or
e
KEY
II
)
ALWAYS PERFORM THIS OPERATION WITH THE DOOR OPEN
If your unit is programmed for Dual Code, each code must be
changed independently.
1 Enter existing code and hold down the last digit until unit
double signals twice and the LED stays on.
2 Press the “0” key.
3 Enter your NEW six (6) digit code two times.
m If a mistake is made wait thirty (30) seconds and repeat steps 1
- 3.
4 Test unit operation several times before closing the door.
Valid Code Entry - Double signal after valid six (6) digit code is
entered.
• Invalid Code Entry - Triple signal and old code is still valid.
MANAGER CODE MUST BE CHANGED PRIOR TO
PERFORMING ANY ACTION OTHER THAN OPENING THE
LOCK
OPENING THE LOCK (Without
e
KEY or
e
KEY
II
)
1 Enter valid six (6) digit code.
2 The unit will indicate a valid code entry with a double signal.
3 Within four (4) seconds open lock by either rotating the keypad
to open position (Clock-wise) or turning the handle to the open
position.
4 Pull door open.
• Invalid Code Entry - Unit will signal three (3) times.
Suggested Keypad
ACTIVATING USER
(Manager Only, without e
KEY or
e
KEY
II
)
ALWAYS PERFORM THIS OPERATION WITH THE DOOR OPEN
1 Enter Manager code and hold down last digit of code until unit
double signals twice and the LED stays on.
2 PRESS 1. Unit signals twice.
3 Press User number, 2 to 9. Unit signals twice.
4 Enter NEW six (6) digit User code two times.
5 If a mistake is made wait thirty (30) seconds and repeat steps
1 - 4.
Valid Code Entry - Double signal after valid six (6) digit code is
entered.
• Invalid Code Entry - Triple signal and old code is still valid.
DISABLE USER
(Manager Only, without e
KEY or
e
KEY
II
)
ALWAYS PERFORM THIS OPERATION WITH THE DOOR OPEN
1 Enter Manager code and hold down last digit of code until unit
double signals twice and the LED stays on.
2 PRESS 2. Unit signals twice.
3 Press User number, 2 to 9. Unit signals once.
4 User is temporarily disabled.
5 If a mistake is made wait thirty (30) seconds and repeat steps
1 - 3.
Valid Code Entry - Double signal after valid six (6) digit code is
entered.
• Invalid Code Entry - Triple signal and old code is still valid.
STANDARD FEATURES
MANAGER CODE
(Factory set to 1-2-3-4-5-6 or 7-8-9
depending on code length)
• Activate/Delete Users
• Enable/Disable Users
• Set Time Delay Values
• Open Lock
USER CODE
• Open Lock
• Change Code
TIME DELAY
• Delay period 1 - 99 minutes
• Open period 1 - 19 minutes
DUAL CODE
Two codes required to open
SIGNAL TO DISABLE LOCK OPENING
(Optional Alarm Box
Required)
• Input signal disables opening of lock by valid code
WRONG TRY PENALTY
• Four (4) consecutive invalid codes initiates five minute
delay period.
LOW BATTERY WARNING
• Repeated audio and visual signal (LED flashing and
repeated beeping) during opening indicates battery low.
AUDIO AND VISUAL SIGNAL
• Double signal (LED flashes and unit beeps) indicates
entry is valid or accepted.
Triple signal indicates invalid or not accepted.
AUDIT TRAIL
• For audit features see LPAUDIT Software Package
3750-K
Round Entry
PC PROGRAMMABLE FEATURES
MULTIPLE USERS
Up to nine (1 Manager and 8 Users)
User # Installed 2 3 4 5 6 7 8 9
ACTIVE
CODE LENGTH
TIME DELAY OVERRIDE
• Ability to add second combination to override delay
period
SILENT SIGNAL ALARM
(Optional Alarm Box Required)
• Duress signal if last number of code(s) is entered using
one number higher or one number lower.
SIGNAL TO DISABLE LOCK
(Optional Alarm Box Required)
• Input signal disables all lock functions by valid code
e
KEY or
e
KEY
II
• Use of key and code required
Lock Choices
4300
Dual-Handed Swingbolt
6040-DB
Deadbolt
All locks are shipped from the factory in Pre Set-up
mode, with no features installed.
Lock will open when 1 is pressed.
Please follow LPAUDIT PC software instructions to
initially configure locks to default settings.
4300 is a new part
number replacing the
6260
3125 Round
Entry
Question and Answer IconNeed help?

Do you have a question about the LG 4300 and is the answer not in the manual?

LG 4300 Specifications

General IconGeneral
BrandLG
Model4300
CategoryDoor locks
LanguageEnglish

Summary

LG AudiT LPAUDIT Manager Programming

Opening the Lock (Without eKEY or eKEYII)

Instructions for opening the lock using a valid six-digit code without eKEY.

Changing Your Code (Without eKEY or eKEYII)

Steps to change the user code on the lock when the door is open.

Activating User (Manager Only, Without eKEY or eKEYII)

Process for a manager to activate a new user code for the lock.

Disable User (Manager Only, Without eKEY or eKEYII)

How a manager can temporarily disable a user's access code.

Reinstate User (Manager Only, Without eKEY or eKEYII)

Procedure for a manager to reinstate a previously disabled user code.

Delete User (Manager Only, Without eKEY or eKEYII)

Steps a manager follows to permanently remove a user's code.

Check User Status (Manager Only, Without eKEY or eKEYII)

How to check if a user code is active, disabled, or available.

Set/Change Time Delay Values (Manager Only, Without eKEY or eKEYII)

Configure delay periods for opening the lock.

Receive Audit (Manager Only, Without eKEY or eKEYII)

Instructions for retrieving audit trail data using serial interface.

Dual Code Operation (Without eKEY or eKEYII)

Requirements for opening the lock when dual code feature is active.

Time Delay Override (Without eKEY or eKEYII)

How to override the time delay period using a specific user code.

Silent Signal Alarm (Without eKEY or eKEYII)

How to activate a duress signal using a modified code.

Opening the Lock (With eKEY or eKEYII)

Instructions for opening the lock using a valid code and eKEY.

Changing Your Code (With eKEY or eKEYII)

Steps to change the user code on the lock when the door is open, using eKEY.

Activating User (Manager Only, With eKEY or eKEYII)

Process for a manager to activate a new user code using eKEY.

Disable User (Manager Only, With eKEY or eKEYII)

How a manager can temporarily disable a user's code using eKEY.

Reinstate User (Manager Only, With eKEY or eKEYII)

Procedure for a manager to reinstate a user code using eKEY.

Delete User (Manager Only, With eKEY or eKEYII)

Steps a manager follows to remove a user's code using eKEY.

Check User Status (Manager Only, With eKEY or eKEYII)

How to check user code status using eKEY.

Set/Change Time Delay Values (Manager Only, With eKEY or eKEYII)

Configure delay periods for opening the lock using eKEY.

Receive Audit (Manager Only, With eKEY or eKEYII)

Retrieve audit trail data using serial interface and eKEY.

Dual Code Operation (With eKEY or eKEYII)

Requirements for opening the lock with dual codes and eKEY.

Time Delay Override (With eKEY or eKEYII)

How to override time delay using a specific user code with eKEY.

Silent Signal Alarm (With eKEY or eKEYII)

How to activate a duress signal using a modified code with eKEY.

Wrong Try Penalty

Consequences of entering invalid codes consecutively.

Battery Low Warning

Indicators and recommendations for low battery conditions.

Changing Your Battery