- 13 -
LGE Internal Use OnlyCopyright © LG Electronics. Inc. All rights reserved.
Only for training and service purposes
4.2. DPM operation confirmation
(Only Apply for MNT Model)
Check if Power LED Color and Power Consumption operate
as standard.
■ Set Input to RGB and connect D-sub cable to set
■ Measurement Condition: (100~240V@ 50/60Hz)
■ Confirm DPM operation at the state of screen without Signal
4.3. EDID DATA
1) All Data : HEXA Value
2) Changeable Data :
*: Serial No : Controlled / Data:01
**: Month : Controlled / Data:00
***:Year : Controlled
****:Check sum
- Auto Download
■ After enter Service Mode by pushing “ADJ” key,
■ Enter EDID D/L mode.
■ Enter “START” by pushing “OK” key.
※ Edid data and Model option download (RS232C)
NO Item CMD 1 CMD 2 Data 0
Enter
download
MODE
Download
‘Mode In’
A A 0 0
When transfer
the ‘Mode In’,
Carry the com-
mand
Edid data
and Model
option
download
Download A E 00 10
Automatically
download
(The use of a
internal Data)
● EDID DATA
1) HD 2D EDID Data
Before S/W version
CheckSum
(0xFF)
Physical Address
(0x1E)
Remark
HDMI 1 74 / 5B 10 LF51 has Only
HDMI1
HDMI 2 74 / 4B 20
- HDMI1/2 (128)
- HDMI1 (256)
- HDMI2 (256)
2) FHD 2D EDID Data (S/W 1.01.20)
CheckSum
(0xFF)
Physical Address
(0x1E)
Remark
HDMI 1 40 / 25 10
HDMI 2 40 / 15 20
- HDMI1/2 (128)
- HDMI1 (256)
- HDMI2 (256)