- 14 -
LGE Internal Use OnlyCopyright © LG Electronics. Inc. All rights reserved.
Only for training and service purposes
4.4. Outgoing condition Configuration
When pressing IN-STOP key by SVC remocon, Red LED
are blinked alternatively. And then automatically turn off.
(Must not AC power OFF during blinking)
4.5. GND & Hi-pot test
4.5.1. GND & HI-POT auto-check preparation
1) Check the POWER CABLE and SIGNAL CABE insertion
condition
4.5.2. GND & HI-POT auto-check
1) Pallet moves in the station. (POWER CORD / AV CORD is
tightly inserted)
2) Connect the AV JACK Tester.
3) Controller (GWS103-4) on.
4) GND Test (Auto)
- If Test is failed, Buzzer operates.
- If Test is passed, execute next process (Hi-pot test).
(Remove A/V CORD from A/V JACK BOX)
5) HI-POT test (Auto)
- If Test is failed, Buzzer operates.
- If Test is passed, GOOD Lamp on and move to next
process automatically.
4.5.3. Checkpoint
1) Test voltage
3 Poles
- GND: 1.5KV/min at 100mA
- SIGNAL: 3KV/min at 100mA
2 Poles
- SIGNAL: 3KV/min at 100mA
2) TEST time: 1 second
3) TEST POINT
3 Poles
- GND Test = POWER CORD GND and SIGNAL CABLE
GND.
- Hi-pot Test = POWER CORD GND and LIVE &
NEUTRAL.
2 Poles
- Hi-pot Test = Accessible Metal and LIVE & NEUTRAL.
4) LEAKAGE CURRENT: At 0.5mArms

Other manuals for LG 49LF5100