Functions
Error Indicator
The function is to self-diagnoisis airconditioner and express the troubles identifically if there is any trouble.
Error mark is ON/OFF for the operation LED of evaporator body in the same manner as the following table.
If more than two troubles occur simultaneously, primarily the highest trouble fo error code is expressed.
After error occurrence, if error is released, error LED is also released simultaneously.
To operate again on the occurrence of error code, be sure to turn off the power and then turn on.
Having or not of error code is different from Model.
Error
Code
Error LED
(Indoor body operation LED)
Error contents SVC check point
1
(once)
3sec 3sec 3sec
5sec
Indoor air temperature thermistor
open/short.
Indoor air TH ass'y check
9
(9times)
3sec
Indoor EEP ROM data (Art type only)
2
(twice)
3sec 3sec
Indoor inlet pipe TH ass'y
check
Indoor inlet pipe temperature thermistor
open/short.
5
(5times)
3sec
(6times)
3sec
Communication line/circuit
Poor communication
6
Indoor outlet pipe TH ass'y
check
Indoor outlet pipe temperature
thermistor open/shor
7
Operate indoor units only
heating or cooling mode.
Defferent Operation (Simultanueous
operation of cooling and heating.
44
Outdoor air TH ass'y check
Replace main PCB DC ASM
Outdoor air temperature thermistor
open/short
45
Outdoor pipe TH ass'y check
Outdoor pipe themperature
thermistor open/short
51
Indoor unit combination check
(Refer to Max. capacity)
Overload combination
(7times)
3sec
3sec 3sec
3sec
3sec 3sec
: ten digits
: one digits
Self-diagnosis Function
Signal Receptor
Signal
receptor
Operation indication lamps
Operation indication lamps
Receives the signals from the remote controller.(Signal receiving sound: two short beeps or one long beep.)
Operation Indication Lamps
Sleep Mode
Timer
Defrost Mode
Outdoor unit operation
PLASMA
Receives the signals from the remote controller.(Signal receiving sound: two short beeps or one long beep.)
Operation Indication Lamps
On/Off
Sleep Mode
Timer
Defrost Mode
OUT
DOOR
OUTDOOR UNIT
OPERATION
On/Off
: Lights up during the system operation.
: Lights up during Sleep Mode Auto operation.
: Lights up during Timer operation.
: Lights up during Defrost Mode or Hot Start operation (Heat pump model only)
: Lights up during outdoor unit operation. (Cooling model only)
: Lights up during the system operation.
: Lights up during Sleep Mode Auto operation.
: Lights up during Timer operation.
: Lights up during Defrost Mode or Hot Start operation.(Heat pump model only)
: Lights up during outdoor unit operation.(Cooling model only)
: Indicate PLASMA purifier operation.

Related product manuals