EasyManua.ls Logo

LG ARNU123TJC2 User Manual

LG ARNU123TJC2
2 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
Date:
JobName/Location:
PONo.:
Architect:
Engr:
GC:
Rep:
For:
File
A
pp
roval
Mech:
Resubmit
Other
(Company)
(ProjectManager)
Tag#:
ARNU123TJC2
MultiV™1WayCeilingCassette
Btu/hIndoorUnit
Performance:
CoolingNominalTestConditions: HeatingNominalTestConditions:
Indoor:
80°FDB/67°FWB
Outdoor
:
95°FDB
Indoor:
70°FDB
Outdoor
:
47°FDB/43°FWB
HeatingCapacity(Btu/h) 13,600
Electrical:
PowerSupply(V/Hz/Ø) 208230/60/1
RatedAmps(A)
0.18
Piping:
Refrigerant:
LiquidLine(in,OD) 1/4Flare
VaporLine(in,OD)
1/2Flare
Condensate:
StandardFeatures:
•LimitedWarrantywithLGCeredInstallaon
•TwoYearFunctionalPartsWarranty
ControlsFeatures:
•Autochangeover
(HeatRecoveryOnly)
•Autooperaon
•Autorestart
•Childlock
•Dualthermistorcontrol
•Groupcontrol
•Forcedoperaon
•Highceiling
•Hotst art
•Selfdiagnoscs
•Sleepmode
•Timer(on/o)
•Weeklyschedule
•Sodry(dehumidicaon)
•Autodirecon/swing(up/down)
•Fanspeedcontrol
•Chaoswind(randomfanspeed)
•Jetcool(fastcooling)
UnitData:
RefrigerantType R410A
RefrigerantControl
EEV
NetUnitWeight(lbs)
25
ShippingWeight(lbs)
34
PrimaryFilter Washableprefilter
SecondaryFilter
Plasma
Fan:
Type CrossFlow
Quantity
1
Motor/Drive
BrushlessDigitallyControlled/Direct
AirflowRateH/M/L(CFM)
283/247/212
O
p
tionalAccessories:
Notes:
1.ThePowerInputisratedathighspeed.
2.Maximumliis27infromboomofunit.
3.SeeEngineeringManualforsensibleandlatentcapacies.
4.SoundPressurelevelsaretestedinananechoicchamberunderISOStandard1996.
5.Allcommunicaoncabletobeminimum18AWG,2conductor,stranded,shieldedandmust
complywithapplicablelocalandnationalcode.
6.Powerwiringcablesizemustcomplywiththeapplicablelocalandnaonalcode.
7.Thisunitcomeswithadrynitrogencharge.
8.Thisdataisrated0abovesealevel,with25ofrefrigerantlineperindoorunitanda0
leveldifferencebetweenoutdoorandindoorunits.Allcapacitiesare net withacombination
raobetween95105%.
9.MustfollowinstallaoninstruconsintheapplicableLGinstallaonmanual.
Re
q
uiredAccessories:
GrilleKit(PTHJC1)
PowerInput¹(W)
40
CondensateLine(in,OD)
1
EnteringMixedAir:
HeatingMin(°FDB) 59
GrilleWeight(lbs)
3
TotalCoolingCapacity(Btu/h) 10,900
FactoryPumpInstalled²
Yes
SoundPressure⁴dB(A)(H/M/L)
40/38/37
CoolingMax³(°FWB)
76
10,900
GrilleShippingWeight(lbs) 8
Page1of2VRFSBDC003US012B09
Forcontinualproductdevelopment,LGreservestherighttochangespecificationswithoutnotice.
LGElectronicsU.S.A.,Inc.,EnglewoodCliffs,NJ.Allrightsreserved.“LGLife’sGood”isaregisteredtrademarkofLGCorp./www.lgvrf.com
WirelessHandheldRemoteController‐PQWRHDF0
7DayProgrammableController(Black)‐PQRCVSL0
SimpleControllerwithMode(Black)‐PQRCVCL0Q
SimpleControllerwithoutMode(Black)PQRCHCA0Q
DryContactUnit‐PQDSB1
WallMountedTemperatureSensor‐PQRSTA0
7DayProgrammableController(White)‐PQRCVSL0QW
SimpleControllerwithMode(White)‐PQRCVCL0QW
SimpleControllerwithoutMode(White)‐PQRCHCA0QW
DryContactUnit‐PQDSBC
Question and Answer IconNeed help?

Do you have a question about the LG ARNU123TJC2 and is the answer not in the manual?

LG ARNU123TJC2 Specifications

General IconGeneral
BrandLG
ModelARNU123TJC2
CategoryAir Conditioner
LanguageEnglish

Summary

ARNU123TJC2 Specifications and Features

Performance Specifications

Details total cooling and heating capacity, plus power input ratings.

Electrical Requirements

Specifies power supply voltage, frequency, phase, and rated amperage.

Piping Connections

Lists the required sizes for liquid and vapor refrigerant lines.

Condensate Management

Details condensate line size and factory pump installation status.

Unit Control Features

Lists various operational modes including auto changeover, restart, and diagnostics.

Entering Mixed Air Conditions

Specifies the maximum cooling wet bulb and minimum heating dry bulb temperatures.

Unit Data Specifications

Provides details on refrigerant type, control, sound pressure, and weights.

Fan Specifications

Details fan type, quantity, motor drive, and airflow rates.

Standard Features and Warranty

Highlights limited warranty and two-year functional parts warranty.

Unit Dimensions and Diagram

Chassis Dimensions

Provides detailed measurements for the unit's chassis components.

Grille Dimensions

Details the measurements for the unit's grille.

Related product manuals