EasyManua.ls Logo

LG ARTCOOL Series - Page 36

LG ARTCOOL Series
49 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
- 35 -
Copyright ©2007 LG Electronics. Inc. All right reserved.
Only for training and service purposes
LGE Internal Use Only
Part 4 Trouble Shooting Guide
6.1 Error indicator of air conditioner
Indoor : Operating LED or 88 Segment,
ex) "C1" Error code 1, C2 Error code 2, "CA" Error code 10,
"CC" Error code 12, CD Error code 13
Outdoor : LED01M(Red) on the outdoor PCB
6.2 Cancellation of Error indicator
1) Error Code 1, 2, 3, 4, 10 : Error code disappear when normal conditions are restored.
2) Error Code 5, 8, 9, 12, 13, 14 : Keep displaying Error code although normal conditions are restored but error code
disappears on restarting the unit.
3) Error Code 6, 7 : Error code disappears when power reset (Power Cord Off & On)
CAUTION
Precaution in Service or Check
Even after stopping the operation of product, it takes some time to discharge the remaining electricity of the electrolyt-
ic capacitor that was charged early.
Before conducting a checking or repairing job, pull out the plug out of the outlet and make sure that the lamp on the
control board outdoor unit is off.

Related product manuals