INSTALLATION MANUAL
AIR CONDITIONER
• Please read this installation manual completely before installing the product.
• Installation work must be performed in accordance with the national
wiring standards by authorized personnel only.
• Please retain this installation manual for future reference after reading
it thoroughly.your set and retain it for future reference.
P/NO : MFL67364301
www.lg.com
MODELS : ARUN Series
ARUV Series
ENGLISH ITALIANO ESPAÑOL
FRANCAIS
DEUTSCH
PORTUGUESE
РУССКИЙ ЯЗЫК

Questions and Answers

  • S
    stacey11Aug 7, 2025
    Why does my LG Air Conditioner show a high pressure error at cooling?
    • E
      Erika JonesAug 7, 2025
      If your LG Air Conditioner's outdoor fan shows a high-pressure error during cooling, it could be due to a motor failure or poor ventilation around the outdoor heat exchanger. First, turn off the outdoor units for a while and then check if the outdoor fan is working. Also, make sure there are no obstructions blocking airflow around the outdoor units.
  • A
    amy45Aug 11, 2025
    What to do if the outdoor EEV in my LG ARUN80LN3 has no operating sound at applying power?
    • B
      Bryan JonesAug 11, 2025
      If the outdoor EEV in your LG Air Conditioner isn't making any operating sounds when power is applied, the coil might have failed. Check the resistance between the terminals to diagnose this issue.
  • J
    James BaileyAug 16, 2025
    Why does the compressor stop during running in my LG ARUN80LN3?
    • R
      Renee GutierrezAug 16, 2025
      If your LG Air Conditioner's compressor stops while running, it might be due to motor insulation failure. Check the resistance between the terminals and the chassis.
  • R
    Rachel WilkersonAug 20, 2025
    What to do if my LG ARUN80LN3 Air Conditioner's outdoor EEV heating fails and defrosts frequently?
    • J
      Jennifer HicksAug 20, 2025
      If the outdoor EEV in your LG Air Conditioner is experiencing heating failure and causing frequent defrosting, it could be due to a bad connector contact. Inspect the connector to resolve this issue.
  • L
    Lisa GonzalezAug 25, 2025
    What to do if LG Air Conditioner's outdoor EEV heating fails and the outdoor heat exchanger part is frozen?
    • J
      James LoweAug 25, 2025
      If your LG Air Conditioner's outdoor EEV is experiencing heating failure and the outdoor heat exchanger part is frozen, the EEV may be clogged. Service is necessary to resolve this issue.
  • A
    Andrew ChapmanAug 29, 2025
    What to do if my LG Air Conditioner's outdoor EEV has low pressure error or discharge temperature error?
    • G
      garymcintoshAug 29, 2025
      If your LG Air Conditioner's outdoor EEV is showing a low-pressure error or discharge temperature error, it could be that the EEV is clogged. Service is necessary to resolve this issue.
  • J
    jenniferprattSep 2, 2025
    How to troubleshoot a non-operating compressor in my LG ARUN80LN3 Air Conditioner?
    • B
      Barbara TownsendSep 2, 2025
      If the compressor in your LG Air Conditioner isn't operating, it could be due to broken motor insulation. Check the resistance between the terminals and the chassis.