26 Room Air Conditioner
Possible Trouble 4 FAN does not operate.
Possible Trouble 5
The function of Energy Saver does not operate.
Exchange IC01M.
Exchange IC01M.
Is the voltage NO.1 or 2 or 4
of IC01M DC 12V?
Is the voltage NO.16 or 15 or 13
of IC01M 0V?
Check the RY-Hi or
RY-Med or RY-Lo.
Check the wiring diagram.
NO
NO
YES
YES
NO
NO
YES
YES
Has the mode
key been pushed once more
after cool mode?
Is the voltage No.3 of
CN-AC/DC of AC PCB
Ass'y DC 5V?
Reference to
OWNER'S MANUAL.
Set the mode key to
Energy Saver mode.
Check the Energy
Saver mode key.
Check the pattern of
AC & DC PCB.
Troubleshooting Guide