Part 4   Trouble Shooting 
- 71 -
Copyright © 2019 - 2020 LG Electronics Inc. 
All rights reserved. Only training and service purposes.
Items for 
checking
Sub-items for 
checking
Checking 
power source
Check-
ing for
over-load 
operation
Checking 
compressor
Checking 
PCBA
Checking 
input 
voltage
Checking 
outdoor 
devices for
shielding
Checking
refrigerant 
for over/short
Checking 
Compressor
wiring
Checking 
IPM 
connection 
state
 Checking 
power 
connection 
state
Checking 
outdoor 
fan operating
condition
Checking 
sensor fault
Checking 
Compressor
phase 
resistance
Checking 
single 
unit of IPM
Checking 
pipes
For bending / 
blocking
Checking 
4-way valve
Checking 
compressor 
Insulation
resistance
Checking 
Compressor
current 
detection circuit
Checking EEV 
for motion
Checking DC 
link voltage
❈ Single-power source : Checking whether  the power is AC 187~276 V.
   3-phase power source : Check whether the line voltage is AC 342~456 V.
❈ Check the manifold gauge pressure
❈ Checking screws 
for no connection or 
unfastening
Flow of trouble diagnosis
6.7 Troubleshooting Outdoor Error 
CH 21 (DC Peak / Comp IPM Fault)