MFL70520315
Rev.00_191125
OWNER'S &
INSTALLATION MANUAL
Original instruction
AIR
CONDITIONER
www.lg.com
Please read this installation manual completely before installing the product.
Installation work must be performed in accordance with the national wiring
standards by authorized personnel only.
Please retain this installation manual for future reference after reading it thoroughly.
Copyright © 2015 - 2019 LG Electronics Inc. All Rights Reserved.
[Representative] LG Electronics Inc. EU Representative :
LG Electronics European Shared Service Center B.V.
Krijgsman 1, 1186 DM Amstelveen, The Netherlands
[Manufacturer] LG Electronics Tianjin Appliances co.,Ltd.
No.09,Jinwei Road,Beichen District,Tianjin,China.
This manual is the simplied version of original manual.
You can obtain the original manual from www.lg.com.
ENGLISH ITALIANO
DEUTSCH
ČEŠTINA
NEDERLANDS
POLSKI
ESPAÑOL
FRANÇAIS
ΕΛΛΗΝΙΚΆ
LIMBA ROMÂNĂ

Table of Contents

Other manuals for LG CL18F

Questions and Answers

  • A
    Andrea RamosAug 7, 2025
    Why is my LG CL18F not cooling or heating effectively?
    • C
      crystal24Aug 8, 2025
      Your LG Air Conditioner may not be cooling or heating effectively because the air filter is dirty. You can find air filter cleaning instructions to resolve this. Also, the room might have been very hot when the air conditioner was first turned on; allow time for it to cool down. Check if the temperature has been set incorrectly or if the indoor unit's air inlet or outlet vents are obstructed.
  • A
    Alex SchultzAug 12, 2025
    Why is my LG Air Conditioner operation noisy?
    • J
      John CollinsAug 12, 2025
      If you hear a noise that sounds like water flowing, it is the sound of freon flowing inside the air conditioner unit. If you hear a noise that sounds like compressed air releasing, it is the sound of the dehumidifying water being processed inside the air conditioning unit.
  • C
    Christina MortonAug 18, 2025
    What to do if the remote control display is faint, or no display at all on my LG CL18F?
    • W
      wayne82Aug 18, 2025
      If the remote control display is faint or has no display at all, check if the batteries are inserted in the opposite (+) and (-) directions. Also, verify whether the circuit breaker has been tripped.
  • T
    ttranAug 22, 2025
    What to do if the error code occurred on my LG Air Conditioner after lightning struck?
    • A
      Amy SchmidtAug 22, 2025
      This product has been applied to the over current protection circuit. Error can occur, but it is normal behavior. After a few minutes, it will operate normally.
  • J
    Joseph MaysAug 28, 2025
    Why does my LG CL18F Air Conditioner not operate for about 3 minutes when restart?
    • A
      amandasharpAug 28, 2025
      This is the protector of the mechanism. Wait about three minutes and operation will begin.
  • S
    Sergio PetersonSep 2, 2025
    What to do if my LG Air Conditioner does not operate?
    • A
      Andrew JohnsonSep 2, 2025
      If your LG Air Conditioner does not operate, check if you have made a mistake in timer operation. Also, verify whether the fuse has blown or the circuit breaker has been tripped.

Summary

Safety Instructions Overview

General Safety Guidelines

Guidelines to prevent risks from unsafe or incorrect operation.

Warning and Caution Definitions

Clarifies 'WARNING' for serious injury/death and 'CAUTION' for minor injury/damage.

Installation and Electrical Safety

Installation Safety Precautions

Safety precautions related to installation work and electrical connections.

Electrical Safety Precautions

Precautions for circuit breakers, grounding, power cables, and capacitors.

Operation Safety

Operation Safety Guidelines

Safety measures during the operation of the air conditioner.

Refrigerant, Connections, and Cleaning Safety

Refrigerant Handling and Connections

Checks for refrigerant leakage, PPE, protection of tubing, and brazing/welding.

Electric Wiring Work

General Wiring Instructions

General rules for field-supplied parts, wiring diagrams, and electrician requirements.

Wiring Connection Procedure

Steps for connecting wires to the control board, matching colors and terminal numbers.

Power Wiring Precautions

Power Wiring Layout Precautions

Guidelines for connecting power wiring to the terminal block, avoiding mixed thicknesses.

Maintenance

Maintenance Safety Precautions

Safety warnings before performing maintenance, like unplugging the power cord.

Troubleshooting and Service

Troubleshooting Common Issues

Common issues and their possible causes, like non-operation or peculiar odors.

Situations Requiring Service

List of critical situations that require contacting service personnel.

LG CL18F Specifications

General IconGeneral
TypeSplit Air Conditioner
RefrigerantR410A
Power Supply220-240V, 50Hz
Cooling Capacity18000 BTU/h
Operating Temperature (Cooling)18°C to 43°C