Part 4 Trouble Shooting
- 75 -
Copyright © 2019 - 2020 LG Electronics Inc.
All rights reserved. Only training and service purposes.
How to check the U, V, and W phase resistance
Measure the line resistance between the compressor
terminals.
Compressor
terminals
Model DKT156MAD DKT208MAB RJB036MAB DJT240MAA
Windings
Resistance
(at 25 ℃)
U-V 1.330±7 % Ω 1.125±7 % Ω 0.529±7 % Ω 0.628±7 % Ω
V-W 1.330±7 % Ω 1.125±7 % Ω 0.529±7 % Ω 0.628±7 % Ω
W-U 1.330±7 % Ω 1.125±7 % Ω 0.529±7 % Ω 0.628±7 % Ω
Windings
Resistance
(at 75 ℃)
U-V 1.620±7 % Ω 1.345±7 % Ω 0.631±7 % Ω 0.758±7 % Ω
V-W 1.620±7 % Ω 1.345±7 % Ω 0.631±7 % Ω 0.758±7 % Ω
W-U 1.620±7 % Ω 1.345±7 % Ω 0.631±7 % Ω 0.758±7 % Ω