25INSTALLATION
ENGLISH
However, since the test performed during
normal operation provides more accurate
information on the condition of the exhaust duct
than the installation test, the number of bars
displayed during the two tests may not be the
same.
• Do not interrupt the test cycle, as this could
result in inaccurate results.
• Even if the Flow Sense indicator does not light up
during the test cycle, some restrictions may still
be present in the exhaust system. Refer to the
Venting the Dryer section of this manual for
complete exhaust system and venting
requirements.
Error Codes
Check the error code before you call for service.
When an error occurs, various LEDs will light up
and a chime will sound.
Restricted or Blocked Airflow
Avoid long runs or runs with multiple elbows or
bends.
Check for blockages and lint buildup.
Make sure the ductwork is not crushed or
restricted.
LED
light
Possible Cause & Solution
Low or
Mediu
m
Temperature sensor failure.
• Turn off the appliance and call for
service.
Energy
Saver
Humidity sensor failure.
• Turn off the appliance and call for
service.
High,
Damp
or
Normal
Electric dryer power cord is not
connected correctly, or house power
supply is incorrect.
• Reset circuit breaker or replace
fuse. Do not increase the fuse
capacity.
House fuse is blown, circuit breaker
has tripped, or power outage has
occurred.
• If the problem is a circuit overload,
have it corrected by a qualified
electrician.
Very Gas supply or service turned off. (Gas
Model only.)
• Confirm that house gas shutoff and
the dryer gas shutoff are both fully
open.
Excess or crushed
transition duct
Too many elbows or
exhaust too long