26 INSTALLATION
appliance will shut off automatically after a
short delay.
Check the Duct Condition
If the Flow Sense
TM
LED is turned on, check the
exhaust system for restrictions and damage.
Repair or replace the exhaust system as needed.
• When the appliance is first installed, this test
should be performed to alert you to any existing
problems with the exhaust duct in your home.
However, since the test performed during
normal operation provides more accurate
information on the condition of the exhaust duct
than the installation test, the results during the
two tests may not be the same.
• Do not interrupt the test cycle, as this could
result in inaccurate results.
• Even if the LED doesn't light up during the test
cycle, some restrictions may still be present in
the exhaust system. Refer to the Venting the
Dryer section of this manual for complete
exhaust system and venting requirements.
Error Codes
Check the error code before you call for service.
Restricted or Blocked Airflow
Avoid long runs or runs with multiple elbows or
bends.
Check for blockages and lint buildup.
Error
Code
Possible Cause & Solution
Temp
sensor
error
Temperature sensor failure.
• Turn off the appliance and call for
service.
Humidity
sensor
error
Humidity sensor failure.
• Turn off the appliance and call for
service.
High
voltage
Low
voltage
Power
supply /
Power
issue
Electric dryer power cord is not
connected correctly, or house
power supply is incorrect.
• Reset circuit breaker or replace
fuse. Do not increase the fuse
capacity.
House fuse is blown, circuit breaker
has tripped, or power outage has
occurred.
• If the problem is a circuit
overload, have it corrected by a
qualified electrician.
Gas
supply
Gas supply or service turned off.
(Gas model only.)
• Confirm that house gas shutoff
and the dryer gas shutoff are both
fully open.
Excess or crushed
transition duct
Too many elbows or
exhaust too long
Error
Code
Possible Cause & Solution