-28-
3. SENSOR RESISTANCE CHARACTERISTICS TABLE
•
The tolerance of sensor resistance is ±5%.
•
Be sure to measure the sensor resistance after keeping the sensor more than 3 minutes at a measuring temperature.
(It needs delay due to sensor speed.)
•
Measure the resistances of SENSORs with a digital tester after disconnecting CON 3 of MAIN PCB ASSY.
MEASURED TEMPERATURE RESISTANCE OF FREEZER SENSOR RESISTANCE OF DEFROST SENSOR, ROOM TEMPERATURE SENSOR
k3.22C°02- Ω 77kΩ
k9.61 C°51- Ω 60kΩ
k0.31 C°01- Ω 47.3k Ω
k1.01 C°5- Ω 38.4k Ω
k8.7 C°0 Ω 30kΩ
k2.6 C°5+ Ω 24.1k Ω
k9.4 C°01+ Ω 19.5k Ω
k9.3 C°51+ Ω 15.9k Ω
k1.3 C°02+ Ω 13kΩ
k5.2 C°52+ Ω 11kΩ
k0.2 C°03+ Ω 8.9k Ω
k4.1 C°04+ Ω 6.2k Ω
k8.0 C°05+ Ω 4.3k Ω