NO COOLING
The Compressor
doesn't run.
Check if the current
flows at the contacting
point of the Thermostat.
Poor contacting point
Replace the
Thermostat.
Check the components
on the main circuit.
Check if the current
flows at the contacting
point of the starting
system.
Poor contacting point
and broken
Replace the device.