TROUBLE DIAGNOSIS
- 101 -
CLAIMS. CAUSES AND CHECK POINTS. HOW TO CHECK
6. Dew and 
ice formation.
7. Sounds
4) Dew on door.
Dew on the duct door. - Duct door heater is cut.
Dew on the dispense 
recess.
Dew on the door surface. Not fully filled. Surface.
Cormer.
P/U liquid contraction.
Dew on the
gasket surface.
5) Water on the floor.
Dew in the refrigerator compartment.
Defrosted water overflows.              Clogged discharging hose.
Discharging hose         Evaporation tray located at wrong place.
location.
Tray drip. Damaged.
Breaks, holes.
Small Capacity.
Position of drain.
1) Compressor compartment operating sounds.
Compressor sound Sound from machine itself.
inserted. Sound from vibration.
Restrainer.
Rubber Too hard.
seat. Distorted.
Aged.
Burnt.
Stopper. Bad Stopper Not fit
assembly. (inner 
diameter
of stopper).
Tilted.
Not 
Compressor base not connected.
Bad welding compressor stand(fallen).
Foreign materials in the compressor 
compartment.
O.L.P. 
sound. 
Chattering 
sound.
Insulation paper vibration.
Capacitor noise.
Pipe contacts each other. – Narrow interval.
Pipe sound. No vibration damper. Damping rubber-Q.
Damping rubber-S.
Capillary tube unattached.
Recess Heater is cut.
Duct door is open. / Foreign material clogging.
Bad wing adhesion. Wing sag(lower part).
Door liner shape mismatch.
Corner. Too much notch.
Broken.
Home Bar heater is cut.
Liquid shortage.
Liquid leak.