The above circuits are circuits attached to freezing room sensor or cold storage room sensor for adjusting setting
temperature at the freezing room and cold storage room, ice-making sensor for sensing water temperature in ice-making, or
an evaporator for sensing temperature of a frost removal sensor necessary for frost removal. Short or open status of every
temperature sensor is as follows:
SENSOR CHECK POINT
NORMAL(-30 °C ~ 50 °C) IN 
SHORT IN OPEN
Freezing sensor POINT  A  Voltage
Frost removal sensor POINT  B  Voltage
Cold storage sensor 1 POINT  C  Voltage
0.5 V~4.5 V 0 V 5 V
Cold storage sensor 2 POINT  D  Voltage
Ice making sensor POINT  E  Voltage
Room temperature sensor POINT  F  Voltage
<GR-P/L207: Dot-LED>
F
A
C
B
D
EXPLATION FOR MICOM CIRCUIT 
- 43 -