EasyManua.ls Logo

LG GR-P257 - MICOM FUNCTION; Control Panel and Basic Functions

LG GR-P257
128 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
1. Monitor Panel
1-1. GR-P257, GR-P217, GR-L257, GR-L217
1-2. GR-C257, GR-C217, GR-B257, GR-B217
2. Description of Function
2-1-1. Funnction of Temperature Selection
* The temperature can vary ±3 °C depending on the load condition.
Whenever pressing button, setting is repeated in the order of (Medium) (Medium Max) (Max) (Min)
(Medium Min).
• The actual inner temperature varies depending on the food status, as the indicated setting temperature is a target
temperature, not actual temperature within refrigerator.
• Refrigeration function is weak in the initial time. Please adjust temperature as above after using refrigerator for minimum
2~3 days.
MICOM FUNCTION
- 25 -
Division Power Initially On 1st Press 2st Press 3th Press 4th Press
Setting
temperature
Temperature
Control
Medium Medium Max Max Min Medium Min
Freezer Control
-19 °C -22 °C -23 °C -15 °C -17 °C
Refrigeration
3 °C2 °C0°C6 °C4 °C
Control
5
4
3
2
1
5
4
3
2
1
5
4
3
2
1
5
4
3
2
1
5
4
3
2
1